Starting Problems; Adjustments 6 - Toro Greensmaster TriFlex 3300 Service Manual

Hide thumbs Also See for Greensmaster TriFlex 3300:
Table of Contents

Advertisement

Starting Problems

Problem
Starter solenoid clicks, but starter will not crank
(if solenoid clicks, problem is not in safety interlock
system).
Nothing happens when start attempt is made.
Greensmaster 3300/3400
Possible Causes
Battery cables are loose or corroded.
Battery ground to frame is loose or corroded.
Battery is discharged or faulty.
Wiring at starter is loose or faulty.
Starter mounting bolts are loose or not supplying a
sufficient ground.
Starter solenoid is faulty.
Starter motor is faulty.
Functional control lever is not in the NEUTRAL
position.
The parking brake is disengaged and the operator seat
is unoccupied.
Battery cables are loose or corroded.
Battery ground to frame is loose or corroded.
Battery is discharged or faulty.
Fuse(s) is (are) faulty.
The fusible link harness at the engine starter motor is
faulty.
Wiring to the start circuit components is loose,
corroded or damaged (see electrical schematic in
Chapter 10 -- Foldout Drawings).
The ignition switch or circuit wiring is faulty.
Starter solenoid or circuit wiring is faulty.
Main power relay or circuit wiring is faulty.
Fuse block is faulty.
Neutral switch is out of adjustment or is faulty.
TEC controller is faulty.
Page 6 - - 17