Ignition Switch (Serial Number Above 312000000); Service And Repairs 6 - Toro Greensmaster TriFlex 3300 Service Manual

Hide thumbs Also See for Greensmaster TriFlex 3300:
Table of Contents

Advertisement

Ignition Switch (Serial Number Above 312000000)

The ignition (key) switch is located on the control panel
and has three (3) positions: STOP, RUN and START
(Fig. 24). The Toro Electronic Controller (TEC) monitors
the operation of the ignition switch.
NOTE: The engine can only be started when the func-
tional control lever is in the NEUTRAL position and ei-
ther the seat is occupied or the parking brake is
engaged. Also, the TEC controller limits engine crank-
ing time to thirty (30) seconds.
Testing
1. Park machine on a level surface, lower cutting units,
engage parking brake and stop engine. Remove key
from ignition switch.
2. Before disconnecting the ignition switch for testing,
the switch and its circuit wiring should be tested as a
TEC electrical input using the Diagnostic Display (see
Diagnostic Display in the Troubleshooting section of this
chapter). If input testing verifies that the ignition switch
and circuit wiring are functioning correctly, no further
ignition switch testing is necessary. If, however, input
testing determines that the ignition switch and circuit
wiring are not functioning correctly, proceed with the fol-
lowing ignition switch testing procedure.
3. Remove console cover from console assembly to
gain access to ignition switch (see Control Console Dis-
assembly in the Service and Repairs section of Chapter
7 -- Chassis).
4. Make sure ignition switch is in the OFF position. Dis-
connect wire harness connector from ignition switch.
5. The ignition switch terminals are identified in Figure
24 and the circuitry of the switch is shown in the chart in
Figure 25. With the use of a multimeter (ohms setting),
the switch functions can be tested to determine whether
continuity exists between the various terminals for each
switch position. Verify continuity between switch termi-
nals.
Greensmaster 3300/3400
6. Replace ignition switch if testing determines that it is
faulty.
7. If the ignition switch tests correctly and a circuit prob-
lem still exists, check wire harness (see Electrical Sche-
matics and Wire Harness Drawings in Chapter 10 --
Foldout Drawings).
8. After testing is complete, connect machine wire har-
ness connector to ignition switch. Secure console cover
to machine with removed fasteners.
STOP
FRONT VIEW
SWITCH
POSITION
STOP
RUN
START
NOTE: Ignition switch terminals 1 and 6 are connected
internally. Terminals 4 and 5 are also connected internal-
ly. These terminals should have continuity regardless of
switch position.
Page 6 - - 27
RUN
START
6
1
2
5
3
4
REAR VIEW
Figure 24
CIRCUITS
1 + 6
1 + 3 + 4 + 5 + 6
1 + 2 + 4 + 5 + 6
Figure 25