Starting Problems

Problem
Engine will not start.
Engine will start, but will not
continue to run.
Greensmaster Flex 21
ponents used on this machine (see Wiring Schematic
section of this chapter).
The interlock switch must not be by–passed, it must be
connected for proper troubleshooting and safety.
any
electrical
NOTE: See the Kawasaki FE120 Service Manual in
Chapter 3 – Engine for troubleshooting of electrical
problems related to the ignition system. Some ignition
system testing is covered in this chapter.
Possible Causes
ON/OFF switch is in the OFF
position or is grounded.
Ignition high tension lead is not
connected.
Electrical wires are loose or
damaged.
Interlock switch is not adjusted or
faulty.
Interlock module is faulty.
Electrical wires are loose or
damaged.
Interlock module is faulty.
Page 5 – 5
Correction
Turn switch to ON or replace switch.
Make sure high tension lead is
connected.
Check electrical connections.
Repair wiring.
Adjust or replace interlock switch.
Replace interlock module.
Check electrical connections.
Repair wiring.
Replace interlock module.