Battery Service - Toro Greensmaster TriFlex 3300 Service Manual

Hide thumbs Also See for Greensmaster TriFlex 3300:
Table of Contents

Advertisement

Battery Service

The battery is the heart of the electrical system. With
regular and proper service, battery life can be extended.
Additionally, battery and electrical component failure
can be prevented.
CAUTION
When working with batteries, use extreme cau-
tion to avoid splashing or spilling electrolyte.
Electrolyte can destroy clothing and burn skin or
eyes. Always wear safety goggles and a face
shield when working with batteries.
Greensmaster 3300 Battery Specifications
BCI Group U1 Battery
300 Amp Cranking Performance at 0
28 minute Reserve Capacity at 80
Electrolyte Specific Gravity (fully charged): from 1.250
to 1.280
Electrolyte Specific Gravity (discharged): 1.240
Greensmaster 3400 Battery Specifications
BCI Group 55 Battery
585 Amp Cranking Performance at 0
95 minute Reserve Capacity at 80
Electrolyte Specific Gravity (fully charged): from 1.250
to 1.280
Electrolyte Specific Gravity (discharged): 1.240
Battery Removal (Fig. 70 or 71)
IMPORTANT: Be careful to not damage terminal
posts or cable connectors when removing the bat-
tery cables.
1. Disconnect the negative cable (--) from the battery
first to prevent short circuiting the battery, other compo-
nents or the operators hands. Then disconnect the posi-
tive (+) cable.
2. Remove fasteners and retainer components that se-
cure battery to frame.
3. Make sure that the filler caps are on tightly.
4. Remove battery from the battery compartment to a
service area. This will minimize possible battery dam-
age and allow better access for inspection and service.
Electrical System
o
o
F (--18
C)
o
o
F (27
C)
o
o
F (--18
C)
o
o
F (27
C)
Page 6 - - 56
GREENSMASTER 3300
Figure 70
1. Battery
2. Hold down rod
3. Post (2 used)
4. Battery tray
5. Wing nut (2 used)
GREENSMASTER 3400
5
Figure 71
1. Battery
2. Battery retainer
3. Flat washer
4. Cap screw
9
6
2
7
5
1
8
4
FRONT
3
6. Hex nut (2 used)
7. Cap screw (2 used)
8. Positive battery cable
9. Negative battery cable
FRONT
6
4
3
2
7
1
5. Flange nut
6. Positive battery cable
7. Negative battery cable
Greensmaster 3300/3400