1.4540.041 – TecJet Internal Fault
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
1.4540.042 – Keyswitch State
Red alarm. Initiated by TecJet.
Cause
Keyswitch cabling missing.
1.4540.043 – Parameter Error
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
1.4540.044 – Parameter Version Error
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
1.4540.045 – Main EEP Read Fail
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
1.4540.046 – Main EEP Write Fail
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
1.4540.047 – Reading Parameters
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
88 | Troubleshooting | MS150114/01E 2015-03
Corrective action
u Restart TecJet.
Corrective action
u Check cabling.
Corrective action
u Restart TecJet.
Corrective action
u Restart TecJet.
Corrective action
u Restart TecJet.
Corrective action
u Restart TecJet.
Corrective action
u Restart TecJet.