MTU 8 V 4000 Lx2 xx Operating Instructions Manual page 60

Table of Contents

Advertisement

112418 – LO T-Exhaust B8
Yellow alarm. Initiated by EMU.
Cause
The exhaust temperature of this
cylinder is too high as compared
with the average value.
112419 – LO T-Exhaust B9
Yellow alarm. Initiated by EMU.
Cause
The exhaust temperature of this
cylinder is too high as compared
with the average value.
112420 – LO T-Exhaust B10
Yellow alarm. Initiated by EMU.
Cause
The exhaust temperature of this
cylinder is too high as compared
with the average value.
112501 – HIHI T-Exhaust A1
Red alarm. Initiated by EMU.
Cause
The exhaust temperature of this
cylinder is too high as compared
with the average value.
112502 – HIHI T-Exhaust A2
Red alarm. Initiated by EMU.
Cause
The exhaust temperature of this
cylinder is too high as compared
with the average value.
112503 – HIHI T-Exhaust A3
Red alarm. Initiated by EMU.
Cause
The exhaust temperature of this
cylinder is too high as compared
with the average value.
60 | Troubleshooting | MS150114/01E 2015-03
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 141).
4. Check valve drive.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 141).
4. Check valve drive.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 141).
4. Check valve drive.
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 141)
3. Check valve drive (exhaust valves do not close).
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 141).
3. Check valve drive (exhaust valves do not close).
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 141).
3. Check valve drive (exhaust valves do not close).

Advertisement

Table of Contents
loading

This manual is also suitable for:

12 v 4000 lx2 xx16 v 4000 lx2 xx20 v 4000 lx2 xx

Table of Contents