112403 – LO T-Exhaust A3
Yellow alarm. Initiated by EMU.
Cause
The exhaust temperature of this
cylinder is too high as compared
with the average value.
112404 – LO T-Exhaust A4
Yellow alarm. Initiated by EMU.
Cause
The exhaust temperature of this
cylinder is too high as compared
with the average value.
112405 – LO T-Exhaust A5
Yellow alarm. Initiated by EMU.
Cause
The exhaust temperature of this
cylinder is too high as compared
with the average value.
112406 – LO T-Exhaust A6
Yellow alarm. Initiated by EMU.
Cause
The exhaust temperature of this
cylinder is too high as compared
with the average value.
112407 – LO T-Exhaust A7
Yellow alarm. Initiated by EMU.
Cause
The exhaust temperature of this
cylinder is too high as compared
with the average value.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 141).
4. Check valve drive.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 141).
4. Check valve drive.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 141).
4. Check valve drive.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 141).
4. Check valve drive.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 141).
4. Check valve drive.
MS150114/01E 2015-03 | Troubleshooting | 57