MTU 8 V 4000 Lx2 xx Operating Instructions Manual page 64

Table of Contents

Advertisement

112602 – LOLO T-Exhaust A2
Red alarm. Initiated by EMU.
Cause
The exhaust temperature of this
cylinder is too low as compared
with the average value.
112603 – LOLO T-Exhaust A3
Red alarm. Initiated by EMU.
Cause
The exhaust temperature of this
cylinder is too low as compared
with the average value.
112604 – LOLO T-Exhaust A4
Red alarm. Initiated by EMU.
Cause
The exhaust temperature of this
cylinder is too low as compared
with the average value.
112605 – LOLO T-Exhaust A5
Red alarm. Initiated by EMU.
Cause
The exhaust temperature of this
cylinder is too low as compared
with the average value.
112606 – LOLO T-Exhaust A6
Red alarm. Initiated by EMU.
Cause
The exhaust temperature of this
cylinder is too low as compared
with the average value.
64 | Troubleshooting | MS150114/01E 2015-03
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 141).
4. Check valve drive.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 141).
4. Check valve drive.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 141).
4. Check valve drive.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 141).
4. Check valve drive.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 141).
4. Check valve drive.

Advertisement

Table of Contents
loading

This manual is also suitable for:

12 v 4000 lx2 xx16 v 4000 lx2 xx20 v 4000 lx2 xx

Table of Contents