MTU 8 V 4000 Lx2 xx Operating Instructions Manual page 66

Table of Contents

Advertisement

112612 – LOLO T-Exhaust B2
Red alarm. Initiated by EMU.
Cause
The exhaust temperature of this
cylinder is too low as compared
with the average value.
112613 – LOLO T-Exhaust B3
Red alarm. Initiated by EMU.
Cause
The exhaust temperature of this
cylinder is too low as compared
with the average value.
112614 – LOLO T-Exhaust B4
Red alarm. Initiated by EMU.
Cause
The exhaust temperature of this
cylinder is too low as compared
with the average value.
112615 – LOLO T-Exhaust B5
Red alarm. Initiated by EMU.
Cause
The exhaust temperature of this
cylinder is too low as compared
with the average value.
112616 – LOLO T-Exhaust B6
Red alarm. Initiated by EMU.
Cause
The exhaust temperature of this
cylinder is too low as compared
with the average value.
66 | Troubleshooting | MS150114/01E 2015-03
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 141).
4. Check valve drive.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 141).
4. Check valve drive.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 141).
4. Check valve drive.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 141).
4. Check valve drive.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 141).
4. Check valve drive.

Advertisement