1.4510.196 – Knock Sensor Error A5
Red alarm. Initiated by anti-knock control.
Cause
No signal from this knock
sensor.
1.4510.197 – Knock Sensor Error A6
Red alarm. Initiated by anti-knock control.
Cause
No signal from this knock
sensor.
1.4510.198 – Knock Sensor Error A7
Red alarm. Initiated by anti-knock control.
Cause
No signal from this knock
sensor.
1.4510.199 – Knock Sensor Error A8
Red alarm. Initiated by anti-knock control.
Cause
No signal from this knock
sensor.
1.4510.200 – Knock Sensor Error A9
Red alarm. Initiated by anti-knock control.
Cause
No signal from this knock
sensor.
1.4510.201 – Knock Sensor Error A10
Red alarm. Initiated by anti-knock control.
Cause
No signal from this knock
sensor.
Corrective action
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
Corrective action
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
Corrective action
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
Corrective action
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
Corrective action
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
Corrective action
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
MS150114/01E 2015-03 | Troubleshooting | 73