ATTO Technology FibreBridge 7500 Installation And Operation Manual

ATTO Technology FibreBridge 7500 Installation And Operation Manual

16-gigabit fibre channel to 12-gigabit sas storage controller
Hide thumbs Also See for FibreBridge 7500:

Advertisement

Quick Links

ATTO FibreBridge
Installation and Operation Manual
ATTO FibreBridge 7500
16-Gigabit Fibre Channel to 12-Gigabit SAS Storage Controller

Advertisement

Table of Contents
loading

Summary of Contents for ATTO Technology FibreBridge 7500

  • Page 1 ™ ATTO FibreBridge Installation and Operation Manual ATTO FibreBridge 7500 16-Gigabit Fibre Channel to 12-Gigabit SAS Storage Controller...
  • Page 2 (716)691-1999 ext. 242 © 2016 ATTO Technology, Inc. All rights reserved. All brand or product names are trademarks of their respective holders. No part of this manual may be reproduced in any form or by any means without the express written permission of ATTO Technology, Inc.
  • Page 3: Table Of Contents

    Contents 1.0 ATTO FibreBridge Overview ..................1 ATTO FibreBridge 7500 features, benefits 1.1 ATTO FibreBridge 7500 ..................2 Dimensions Cooling and airflow Power Fibre Channel ports SAS/SATA ports Management ports LED indicators 2.0 Install the FibreBridge ...................4 Unpack the packing box; verify contents...
  • Page 4 Appendix B CLI Provides ASCII-based Interface ............ii CLI error messages CLI summary reference Command explanations Appendix C Standards and Compliances ..............xvi Regulatory Notices FCC Notices (US only) Compliance with ICES-003 Compliance with EN Regulations Appendix D Warranty Information ................xiv ATTO Technology, Inc. limited warranty...
  • Page 5: Atto Fibrebridge Overview

    The ATTO FibreBridge™ 7500 is a storage controller that connects multiple shelves of SAS and SATA JBOD storage and virtualizes it to a Fibre Channel SAN Connection. The ATTO FibreBridge 7500 allows IT departments to (Storage Area Network) and has undergone...
  • Page 6: Atto Fibrebridge 7500

    1.1 ATTO FibreBridge 7500 The ATTO FibreBridge 7500 is a high-performance storage controller which adds 16-Gigabit Fibre Channel connectivity to 12-Gigabit SAS or SATA storage devices. SAS/SATA ports The FibreBridge 7500 is available in an industry- standard 1U form factor for easy integration into racks.
  • Page 7 LEDs on the faceplate are: Ready: A lit green LED indicates ready and OFF to show not ready. Power Supplies: One LED for each supply. Green Alert: A lit yellow LED indicates an alert condition. indicates on and ready while amber indicates an Fibre Channel Port Activity: A lit green FC port unplugged or failed supply.
  • Page 8: Install The Fibrebridge

    Failure to do so may cause injury or If a DHCP server is available on your network, damage the unit. an address is assigned automatically by the server. Note the assigned address: _____________________________________ ATTO Technology Inc. FibreBridge Installation and Operation Manual...
  • Page 9: Internet Explorer Setup

    Click on Enter Here. Type in the user name and password. Note The default values are user name root and password Password. The user name is case insensitive and the password is case Exhibit 2.0-3 FibreBridge 7500, LEDs, power receptacle and ports...
  • Page 10: Installation And Removal Of Power Supply Modules

    Press the side latch inward and pull out on the handle Install power cord. Exhibit 2.0-4 CAUTION CAUTION Remove the power source before removing the power supply module. Failure to do so may cause injury or damage the unit. ATTO Technology Inc. FibreBridge Installation and Operation Manual...
  • Page 11: Configure The Fibrebridge

    3.0 Configure the FibreBridge To configure the ATTO FibreBridge, use the ATTO ExpressNAV System Manager GUI. Default values are appropriate for most configurations, but may be modified. The best way to access the FibreBridge to view • Use the individual pages listed on the side menu to make changes or use other features and change settings is to use ATTO ExpressNAV such as Email notification or SNMP as...
  • Page 12 Confirm New Read Only Password text If you have completed all changes for this boxes. session, go to the Restart page and restart the FibreBridge. Click Submit. ATTO Technology Inc. FibreBridge Installation and Operation Manual...
  • Page 13: Map Devices

    Arbitrated Loop Port Address (AL_PA). Each device on an arbitrated loop is When using the FibreBridge 7500 with a device that assigned a unique AL_PA during loop initialization. supports multiple LUNs behind a target, such as a...
  • Page 14: Automap Devices

    location whenever a drive or shelf is added or failure and remain consistent during power cycles of removed. This allows maps to remain the same when the FibreBridge. shelves or drives need to be swapped out due to AutoMap devices If you are not already in the ExpressNAV interface, type the IP address of your If you are not already in...
  • Page 15: Remote Monitoring, Management

    Messages may state that a device is not working, a • None: no messages are sent medium has an error, or a command has been stopped. Exhibit 3.0-3 The Remote Management page in the ExpressNAV System Manager. ATTO Technology Inc. FibreBridge Installation and Operation Manual...
  • Page 16: Snmp-Based Monitoring

    SNMP-based monitoring The Simple Network Management Protocol (SNMP) On the left-hand menu, click Remote facilitates the exchange of management information Management. between network devices. The Remote Management page appears. An agent residing in the FibreBridge takes information Click on the enabled radio button next to the from the FibreBridge and translates it into a form SNMP heading.
  • Page 17: Email Messages Provide Error Notification

    *************** Unit Information *************** Serial Number : [Serial Number] IP Addresses: [IP Address1] [IP Address2] *************** Event Log Entries **************** ATTO Technology Inc. FibreBridge Installation and Operation Manual...
  • Page 18: Update Firmware

    Active mode and Binary mode for the transfer to complete correctly. The FibreBridge firmware is distributed as a .zbd file from the ATTO Technology web site at Use the PUT command to download the www.attotech.com. Download the file and note the firmware file to the bridge.
  • Page 19: Interface Options

    HyperTerminal on a computer running a select the following values: Windows operating system, • Bits per second: 115200 a. Type FibreBridge in the New • Data Bits: 8 Connection dialog box. • Parity: None ATTO Technology Inc. FibreBridge Installation and Operation Manual...
  • Page 20: Using Telnet

    • Stop Bits: 1 resting. No user name or password is required for serial port access. • Flow Control: None To verify that you have connected successfully, • Terminal type: ASCII type help after the Ready prompt and press • Echo: on Enter.
  • Page 21: Appendix A Cabling

    All cable types listed on this page are available 16Gb/s 8Gb/s 4Gb/s Cable Type on the ATTO web store at 62.5 µm www.attotech.com/store 50 µm 150m 50 µm 100m 150m 380m 50 µm 125m 190m 400m ATTO Technology Inc. FibreBridge Installation and Operation Manual...
  • Page 22 Appendix B CLI Provides ASCII-based Interface The command line interface (CLI) provides access to the ATTO FibreBridge Services through a set of ASCII commands. CLI commands may be entered while in CLI mode. FibreBridge Services provide configuration and • The set form is an action that changes the value monitoring for the FibreBridge.
  • Page 23 100 EventLogFilter get eventlogfilter Exit exit FCConnMode loop set fcconnmode all ptp FCDataRate auto get fcdatarate 1 FCHard disabled set fchard enabled FCHardAddress fp1=3 set fchardaddress 1 122 fp2=4 ATTO Technology Inc. FibreBridge Installation and Operation Manual...
  • Page 24 Command Default Example FCPortErrors get fcporterrors all FCPortList fcportlist FCSCSIBusyStatus busy get fcscsibusystatus FCSFPInfo get fcsfpinfo all FCWWName get fcwwname 1 FirmwareRestart firmwarerestart FlashImages flashimages Help help automap HGAddInitiator HGAddInitiator [HostGroupName] [WWN] HGAddLUN HGAddLUN [HostGroupName] [lun] HGCreate HGCreate [HostGroupName] HGDelete HGDelete [HostGroupName | all] HGDisplay HGDisplay [HostGroupName | all]...
  • Page 25 Fibre Channel ports. The value "0" constitutes no previous maps will be deleted. delay. AutoMap Default: 0 (no delay) Requires a SaveConfiguration command set BootFibreDelay [0-255] Requires a SaveConfiguration command get BootFibreDelay ATTO Technology Inc. FibreBridge Installation and Operation Manual...
  • Page 26 BridgeModel DeleteAllMaps BridgeModel reports the specific model and firmware Removes all mapped devices from the map table. Upon the information to the CLI. subsequent POST, if no maps are present the default maps will be loaded. get BridgeModel DeleteAllMaps Requires a SaveConfiguration command BridgeLun BridgeLun controls the automatic generatrion of a bridge device DisplayInitiators...
  • Page 27 FCHardAddress [fp | all] “factory” to display all events, or specify “user” to display only user events. set EventLogFilter [subsys | all] [[info | warn | crit] [factory | user]] | none] get EventLogFilter ATTO Technology Inc. FibreBridge Installation and Operation Manual...
  • Page 28 FCPortErrors HGAddInitiator FCPortErrors displays the number of Fibre Channel errors that Adds an initiator to an existing Host Group. WWN specifies the have occurred since the last reboot/power-on or world-wide name of the FC Port to be added to the Host Group; ResetFCPortErrors command at the Fibre Channel controller the CLI command “DisplayInitiators”...
  • Page 29 Returns the “name” (the contents of the first record) of the OEM is disabled, then this value must be manually set. configuration file stored in persistent memory. set IPDNSServer [xxx.xxx.xxx.xxx] get oemconfigfile get IPDNSServer ATTO Technology Inc. FibreBridge Installation and Operation Manual...
  • Page 30 OpTempWarn ReadOnlyUsername Regulates/displays the number of degrees in Celsius before a Specifies user name for all Telnet, FTP and ExpressNAV user warning is sent to the user. Valid entries are between 0 degrees management console sessions. Username is case and 15 degrees. insensitive, 1-32 characters, no spaces.
  • Page 31 SNMPTrapAddress [Index] [IPAddress] [None | All | Default: 115200 Warning | Critical ] set SerialPortBaudRate [ 9600 |19200 | 38400 | 57600 | get SNMPTrapAddress [index] 115200] Requires a SaveConfiguration Restart command get SerialPortBaudRate ATTO Technology Inc. FibreBridge Installation and Operation Manual...
  • Page 32 SNMPTraps TimeZone Controls SNMP trap functions.Consult your network Controls/displays the time zone if SNTP is disabled. Setting administrator for further assistance with SNMP. may be EST, CST, MST PST or a numerical offset from GMT in the format +/- HH:MM. When SNTP is enabled, applies the Default: disabled...
  • Page 33: Regulatory Notices

    ATTO device to the EMC Directive and the Low Voltage Directive of the European Union. The ATTO FibreBridge 7500 complies with Directive 2011/65/EC on the Restriction of the Use of Hazardous Substances in Electrical and Electronic Equipment RoHS2 (recast) and take the following exemptions: 6(c)- Copper allot containing up to 4% lead by weight.
  • Page 34 The product has been certified and bears the Mark, as applicable, of the EMC and Product Safety authorities as indicated below: Safety: TUV 72141224, EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations) Emissions/Immunity: FCC Part 15 Class B, ICES-003, CE - EN55022, EN55024, IEC61000-3-2, IEC61000-3-3 ATTO Technology Inc. FibreBridge Installation and Operation Manual...
  • Page 35: Appendix D Warranty Information

    ATTO Technology, Inc. limited warranty ATTO Technology, Inc. (“ATTO”) warrants to the original purchaser of this product (“Product”) that the Product is free from defects in material and workmanship for the term described for this specific Product on ATTO's website (www.attotech.com).