ATTO Technology FibreBridge 7500 Installation And Operation Manual page 27

16-gigabit fibre channel to 12-gigabit sas storage controller
Hide thumbs Also See for FibreBridge 7500:
Table of Contents

Advertisement

EmailPassword
EmailPassword sets the password used to authenticate the
login to the SMTP email server. The password must not be more
than 64 characters. A password is not required if the email
server does not require authentication.
set EmailPassword
Requires a SaveConfiguration command
EmailServerAddress
EmailServerAddress configures the address of the server that
should be contacted in order to send out emails. Either an IP
address or a fully qualified domain (e.g. mail.myserver.com)
may be specified.
set EmailServerAddress [IP address]
Requires a SaveConfiguration command
get EmailServerAddress
EmailUsername
EmailUsername sets the username used to authenticate the
login to the SMTP email server. The username must not be
more than 128 characters. A username is not required if the
email server does not require authentication.
set EmailUsername [username]
Requires a SaveConfiguration command
get EmailUsername
EthernetSpeed
EthernetSpeed determines the speed of any Ethernet port(s). If
Auto is enabled then the Ethernet speed will be negotiated and
the value in parentheses returned by the 'get' command
indicates the current speed of the Ethernet connection.
Default: auto
set EthernetSpeed [mp[n]] [10 | 100 | 1000 | auto]
Requires a SaveConfiguration Restart command
get EthernetSpeed [mp[n] | all]
If auto enabled, returned value in parentheses indicates
current speed
EventLogFilter
Specifies what events to include in the event log display. Type
"get EventLogFilter" for a list of valid subsystems. Specify a
subsystem with "none" to disable event display for that
subsystem. Levels are "info", "warn" and "crit". Specify "info" to
display all levels, "warn" to display warnings and critical events,
"crit" to display only critical events. Events are classified
"factory" or "user" (factory events provide detailed information
for factory debug, and they are marked with a dash.) Specify
"factory" to display all events, or specify "user" to display only
user events.
set EventLogFilter [subsys | all] [[info | warn | crit] [factory
| user]] | none]
get EventLogFilter
vii
ATTO Technology Inc. FibreBridge Installation and Operation Manual
Exit
Exit terminates the current CLI session over Telnet. This
command has no effect if used during a serial RS-232 session.
exit
FCConnMode
FCConnMode specifies the connection mode used when
communicating across a Fibre Channel network. The system
will connect to an arbitrated loop (FC_AL) if 'loop' is selected.
The system will connect in point-to-point mode if 'ptp' is
selected. The options of 'loop-ptp' (AL Preferred) and 'ptp-loop'
(PTP Preferred) allow auto-negotiation while indicating a
preference. Loop mode cannot be specified if FcDataRate is set
to 16Gb.
Default: loop
set FCConnMode [fp | all] [loop | ptp | loop-ptp | ptp-loop]
Requires a SaveConfiguration Restart command
get FCConnMode [fp | all]
FCDataRate
FCDataRate specifies the Fibre Channel data rate (4Gb, 8Gb or
16Gb) or auto-negotiation to the highest speed (auto). 16Gb
cannot be specified when FcConnMode is set to 'loop'.
Default: auto
set FCDataRate [fp | all] [4Gb | 8Gb | 16Gb | auto]
Requires a SaveConfiguration Restart command
get FCDataRate [fp | all]
FCHard
FCHard enables and disables Fibre Channel hard address
assignment. When FCHard is enabled, the internal hard
address will be used as the loop address on the Fibre Channel
loop. Under soft addressing, the loop address is assigned
during loop initialization.
Default: disabled
set FCHard [enabled | disabled]
Requires a SaveConfiguration Restart command
get FCHard
FCHardAddress
FCHardAddress specifies the value used as the FC-AL hard
address. This value represents the address that will be used if
hard addressing is enabled. The range of valid Fibre Channel
Hard Address values is 0 through 125.
Default
fp1=3; fp2=4
set FCHard Address [fp | all] [address]
Requires a SaveConfiguration Restart command
get FCHardAddress [fp | all]

Advertisement