Alarm Task Editor; Alarm Rules - Bosch Autodome IP 4000 HD Software Manual

Hide thumbs Also See for Autodome IP 4000 HD:
Table of Contents

Advertisement

AUTODOME IP 4000 HD / AUTODOME
IP 5000 HD / AUTODOME IP 5000 IR
Note: The name must include at least two character groups separated by a blank (for example,
Parking Garage) in order for the system to generate an email from that name, as in "From
Parking Garage". Text with only one group of characters (for example, Lobby) will not
generate an email.
Test e-mail
You can test the e-mail function by clicking the Send Now button. An alarm e-mail is
immediately created and sent.
8.5

Alarm Task Editor

Caution!
Editing scripts on this page overwrites all settings and entries on the other alarm pages. This
!
procedure cannot be reversed.
In order to edit this page, you must have programming knowledge and be familiar with the
information in the Alarm Task Script Language document.
As an alternative to the alarm settings on the various alarm pages, you can enter your desired
alarm functions in script form here. This will overwrite all settings and entries on the other
alarm pages.
1.
2.
3.
8.6

Alarm Rules

An alarm rule can define which input(s) activate which output(s). Basically, an alarm rule
allows you to customize the camera to respond automatically to different alarm inputs.
To configure an alarm rule, specify one input from a physical connection, from a motion
detection trigger, or from a connection to the camera's LIVE page. The physical input
connection can be activated by dry contact devices such as pressure pads, door contacts, and
similar devices.
Next, specify up to two (2) rule outputs, or the camera's response to the input. Outputs
include a physical alarm output, an AUX command, or a preposition scene.
1. Click the check box Enabled to activate the alarm.
2. Click Input 1 (a physical alarm connection).
3. Select the appropriate input:
Bosch Security Systems
Click the Examples link under the Alarm Task Editor field to see some script examples. A
new window will open.
Enter new scripts in the Alarm Task Editor field or change existing scripts in line with your
requirements.
When you are finished, click the Set button to transmit the scripts to the unit. If the
transfer was successful, the message Script successfully parsed is displayed over the
text field. If it was not successful, an error message will be displayed with further
information.
Alarm input: If you select this option, then a second Input field (a physical alarm
connection) appears to the right, with the options 1: Input 1 or 2: Input 2.
Day/night
IVA/MOTION+: If you select this option, then an alarm will begin when IVA or motion
detection is activated.
Connection: If you select this option, then an alarm will begin when an attempt is made
to access the camera's IP address.
Time: If you select this option, then an input field appears to the right. In this field, enter
the time for the activation of the alarm in hours and minutes. (The default value is 00:00.)