3.0

Installation

3.1

Before You Begin

This section contains a general installation procedure. It refers to other sections of the guide for detailed instructions.
Bosch Security Systems recommends you review this guide and the D6412/D4412 Program Entry Guide (P/N: 45351) before
you begin installation to determine the hardware and wiring requirements for the features you want to use.
As you read through this guide, have the following documents at hand:
• D6412 Program Record Sheet (P/N: 45350) or D4412 Program Record Sheet (P/N: 50485)
• User's Guide (Text Command Center [P/N: 46841]; LED Command Center - 46840). A condensed version of the
User's Guide is found in the D6412/D4412 Program Entry Guide (P/N: 45351).
• Installation guide for each command center model you intend to install.
Before you begin installing the panel, you should be familiar with keypad programming or the Remote Account Manager
(RAM IV).
3.2

Enclosure Options

The D2203 Enclosure is supplied with the standard D6412/D4412 Control Panel. To mount the D6412 in one of the Bosch
Security Systems enclosures listed below, order the D6412M version (order the D4412M version for the D4412).
• D8103 Universal Enclosure (gray)
• D8109 Fire Enclosure (red)
• D8108A Attack Resistant Enclosure (gray)
The "M" version substitutes a D2202 Mounting Skirt for the D2203 enclosure allowing installation in the other enclosures.
"M" does not include a transformer. Order a CX4010 separately. Refer to Appendix A: Approved Applications Compliance
Guide to determine if your application requires a specific enclosure.
Mount the enclosure in the desired location.
3.3

Premises Wiring

Run the necessary wiring throughout the premises and route the wires into the enclosure.
Electro Magnetic Interference (EMI) may cause problems. EMI may occur if you install the system or run system
wires near the following:
• Computer network system
IMPORTANT
• Electrical lines, fluorescent fixtures or telephone cabling
• Ham radio transmitter site
• Heavy machinery and motors
• High voltage electrical equipment or transformers
• PBX telephone system
• Public service (police, fire departments, etc.) using radio communications
• Radio station transmitter site or other broadcast station equipment
• Welding shop
If you think that EMI may be a problem, use shielded cable. The drain wire for the shielded cable must have continuity from
the earth ground terminal on the panel to the end of the wire run. If continuity is not maintained, the shielded cable may
aggravate potential noise problems rather than eliminate them.
Connecting the drain wire to ground at any place other than the earth ground terminal may also produce problems. If you
cut the drain wire to install devices, be certain to splice it together. Carefully solder and tape all splices.
© 2003 Bosch Security Systems
D6412/D4412 Operation and Installation Guide
Page 15
D6412/D4412
Installation
45349E