Main
Sub
Contents
code
code
43
01
Fusing temperature setting
(Normal copy)
04
Fusing temperature setting
in multi copy
[Function]
Used to set the fusing temperature of 3rd or later sheet. (For 1st and 2nd sheets, SIM 43-14 is
used.)
When this simulation is executed, the current set code number is displayed. Press [ ] [ ] key
(or [Numeric] key for the AL-2050/2060) to change the setting and press [OK]/[START] key to
save the setting into the EERPOM. The machine goes into the sub code entry standby mode.
The [Exposure mode selector] key (or [
the mode.
Code
Set temperature (°C)
0
1
2
3
4

Main cassette paper feed

Manual paper feed
* The cassette feed and the manual feed are controlled similarly.
[Operation]
AL-2050/2060
1) Initial display <Main cassette paper feed
setting>
43-01 FU TEMP
TRAY1
2) [
] [
] key: Mode selection
43-01 FU TEMP
MFT
3) [Numeric] key: Value entry
43-01 FU TEMP
MFT
[Function]
For 20th sheet or later in multi copy, the fusing temperature is automatically changed from the
temperature set with simulation 43-01 to the temperature set with this simulation.
When this simulation is executed, the current set code number is displayed. Enter the code
number and press [OK]/[START] key to change the setting.
Code
0
1
2
3
4
5
6
7
Main cassette paper feed
Manual paper feed
Main cassette paper feed (small-size)
Manual paper feed (small-size)
∗ The cassette feed and the manual feed are controlled similarly.
[Operation]
The operation is similar to simulation 43-01.
AL-2020/2035/2040/2050/2060 SIMULATION, TROUBLE CODES 10 - 16
Details of function/operation
] [
Remark
170
175
180
185
190
Mode
6( 0-8 )
6( 0-8 )
6( 0-8 )
Set temperature (°C)
Remark
165
170
175
180
185
190
195
200
Display item
Mode
(AL-2050/2060)
TRAY1 SH
MFT SH
] key for the AL-2050/2060) is used to select
Code
Set temperature (°C)
5
195
6
200
7
205
8
210
Display item
Display item
(AL-2050/2060)
(AL-2020/2035/2040)
TRAY1
AE mode lamp
MFT
TEXT mode lamp
4) [OK]/[START] key
Settles the entered value. The display is
shifted to the sub code input standby
menu.
AL-2020/2035/2040
1) Press [Exposure mode selector] key to
change the mode.
2) Press [ ] [ ] key to set the value.
3) Press [START] key to fix the code
number.
Display lamp
(AL-2020/2035/2040)
TRAY1
AE mode lamp
MFT
TEXT mode lamp
PHOTO mode lamp
AE mode lamp
TEXT mode lamp
Remark
Default
Default
3
3
1
1