Sharp AL-2020 Service Manual page 164

Digital multifunctional system
Hide thumbs Also See for AL-2020:
Table of Contents

Advertisement

SW34 No.1, No.2 Flash send wait time
(U.K., Netherlands, Luxembourg, Belgium, France:
Inhibited to use)
Used to set the time from off-hook to Flash send.
Default: 1 0 (1sec)
SW34 No.3, No.4 Inhibited to use
SW34 No.5–No.8 Signal send level Max.
Used to set the max. signal send level.
Default: –8dBm
SW35 No.1 Cover function default setup
Used to set whether cover is added as default or not.
When auto clear is made by pressing [Clear All] key, the machine
returns to this setting.
Default: 0 (No)
SW35 No.2 Inhibited to use
SW35 No.3, No.4 CI delete max. OFF time
Used to set the max. wait time between detection of CI signal pulse
(number of times) and detection of the next CI signal pulse.
If CIK signal pulse is not detected within this time, the number of
calls up to that time is cleared.
Default: 0 1 (10sec)
SW35 No.5–No.8 Answering machine call number
setting
Used to set the number of calls to switch to auto receive when
answering telephone is not called in when the receive mode is set to
the answering telephone connection mode.
Setting is made in binary input.
Default: 6 times
SW36 No.1–No.8 CNG detection completion time
Used to set the time for completion of CNG signal/mute detection in
the answering telephone connection mode.
Count is made from the last call signal.
Setting is made in binary input.
Default: 45sec
SW37 No.1–No.8 Inhibited to use
SW38 No.1, No.2 Protocol monitor
Used to set whether communication protocol result is printed or not
after completion of communication.
Default: 0 0 (Not printed.)
SW38 No.3 Protocol monitor save
Used to set whether the protocol monitor of the last communication
is saved or not. When set to "Saved," the previous protocol monitor
can be printed with SIM 66-21.
Default: 1 (Yes)
SW38 No.4 Inhibited to use
SW38 No.5, No.6 Flash send time (U.K., Netherlands,
Luxembourg, Belgium, France: Inhibited to use)
Used to set the Flash send time.
Default: 0 0 (90ms)
SW38 No.7 Transfer function
Used to set whether transfer function is enabled or not.
Default: 1 (Allow)
SW38 No.8 Inhibited to use
SW39 No.1–No.3 Inhibited to use
SW39 No.4–No.8 DTMF signal send time
Used to set DTMF signal send time.
Setting is made in binary input by the increment of 10ms.
Default: 80ms
AL-2020/2035/2040/2050/2060 FAX SOFT SWITCH 12 - 26
SW40 No.1–No.8 Number of times of recall in error
Used to set the number of times of recall when a communication
error occurs.
Setting is made in binary input.
When set to 0, recall is not made.
Default: 1 times
SW41 No.1–No.8 Number of times of recall in busy
Used to set the number of times of recall when busy tone is detected
during transmission.
Setting is made in binary input.
When set to 0, recall is not made.
Default: 2 times
SW42 No.1 Inhibited to use
SW42 No.2 FAX receive auto select by CNG detection
Used to set whether FAX receive auto select is enabled or not when
CNG signal is detected with external telephone used.
Default: 1 (Allow)
SW42 No.3 Auto receive select in answering telephone
connection mode
Used to set whether auto receive select function in answering tele-
phone connection mode is enabled or not.
Default: 0 (Inhibit)
SW42 No.4–No.7 Inhibited to use
SW42 No.8 V.34 mode function in manual
communication
Used to set whether V.34 mode is enabled or not in manual commu-
nication.
When, however, SW43-1 is set to "0: OFF," V.34 mode is disabled
even tough this switch is set to "1: ON."
Default: 1 (ON)
SW43 No.1 V.34 mode function
Used to set whether V.34 mode is enabled or not as a capacity of
own machine in send/receive.
Default: 1 (ON)
SW43 No.2, No.3 Inhibited to use
SW43 No.4–No.6 Symbol speed mask in V.34 receive
Used to set symbol speed mask in V.34 receive.
Default: 1 0 1 (3429)
SW43 No.7, No.8 Inhibited to use
SW44 No.1–No.4 V.34 primary channel send speed
Used to set send start speed in V.34 send.
Setting is made in binary input of N in "2400 (bps) x N" in the range
of 2400bps – 33600bps.
N is set in the range of 0 – 15. When set to 0, 2400bps; when set to
15, 33600bps.
When set to 2400bps, all of SW91 No. 1 – 8 must be set as "Dis-
able".
Default: 33600bps
SW44 No.5–No.8 V.34 primary channel receive speed
Used to set receive start speed in V.34 receive.
Setting is made in binary input of N in "2400 (bps) x N" in the range
of 2400bps – 33600bps.
N is set in the range of 0 – 15. When set to 0, 2400bps; when set to
15, 33600bps.
When set to 2400bps, all of SW43 No. 4 – 6 must changed to 2400.
Default: 33600bps
SW45 No.1 FAST mode
Used to set whether FAST function is enabled or not.
Default: 0 (No)