SW
Data
Item
NO.
No.
1
Inhibited to use
2
3
G3 send data
accumulation wait time
S
W
4
5
5
Pause time setup
6
7
8
1
ECM
2
CED signal send
3
CSI transmission
4
DIS reception confirmation
in G3 send
S
5
Inhibited to use
W
6
EOL detection timer
6
7
Countermeasure for echo
in reception (CED tone
send interval)
8
Countermeasure for echo
in transmission (After
reception of DIS, hold time
up to signal send is set.)
1
Dial tone ON/OFF
detection time lower limit
(Intermittent detection)
2
Dial tone detection
3
Busy tone detection
4
Dial tone monitoring time
S
5
Dial tone ON/OFF
W
detection time upper limit
7
(Intermittent detection)
6
Max. length of reception
7
Destination display time
when one-touch key is
pressed
8
1
Memory transmission/
direct transmission default
setup
2
Proxy reception
3
Inhibited to use
4
Quick online send
S
W
5
Remote select function
8
6
Number of times of CNG
detection
7
8
1
Print of total
communication time and
total pages
2
Inhibited to use
S
3
Ringing volume pattern
W
number
4
9
5
6
7
8
Switch selection and contents of functions
Bit No.
3 4
6sec
0 0
5sec
0 1
4sec
1 0
3sec
1 1
Binary input
Bit No.
5 6 7 8
Set range
1 to 15sec
1: Yes
0: No
1: Yes
0: No
1: Yes
0: No
1: 2 times
0: Once in NFS reception,
2 time in DIS reception
1: 25sec
0: 13sec
1: 500ms
0: 75ms
1: 800ms
0: 500ms
1: 300ms
0: 100ms
1: Yes
0: No
1: Yes
0: No
1: 10sec
0: 5sec
1: 400ms
0: 700ms
1: No limit
0: 1.5m
Bit No.
7 8
2sec
0 0
4sec
0 1
6sec
1 0
1: Direct transmission
0: Memory transmission
1: Yes
0: No
1: Yes
0: No
1: Yes
0: No
Binary input
Bit No.
6 7 8
Set range
1 to 4 times
1: Yes
0: No
Binary input
Bit No.
3 4 5 6 7 8
Set range
Pattern No. 1 to 35
AL-2020/2035/2040/2050/2060 FAX SOFT SWITCH 12 - 3
Initial value
Remark
0
0
0
6sec
0
0 When a value outside
the set range is set,
0
2sec
the initial value is set.
1
0
Yes
1
Yes
1
Yes
1
Once in NFS
reception, 2 time
0
in DIS reception
0
13sec
0
500ms
1
500ms
0
100ms
0
No
0
Yes
1
5sec
0
700ms
0
1.5m
0
When a value outside
0
the set range is set,
2sec
the initial value is set.
0
Memory
0
transmission
Yes
1
0
Yes
1
Refer to User program
"REMOTE
Yes
1
RECEPTION
SELECT".
0 When a value outside
the set range is set,
3 times
1
the initial value is set.
1
Yes
1
0
0 When a value outside
the set range is set,
0
the initial value is set.
0
1
0
0
1