Sharp AL-2020 Service Manual page 105

Digital multifunctional system
Hide thumbs Also See for AL-2020:
Table of Contents

Advertisement

Main
Sub
Contents
code
code
41
06
OC cover float detection
level adjustment
(excluding AL-2020)
07
OC cover float detection
margin setting
(excluding AL-2020)
[Function]
When this simulation is executed, the current set value is displayed. When [OK]/[START] key is
pressed, the mirror base unit moves to the SPF/RSPF scan position to acquire the OC cover
float detection level.
When the mirror base unit returns to the home position, the acquired value is displayed.
If the adjustment is NG, the following message is displayed.
AL-2035/2040: Misfeed lamp lights up, and the 7seg display remains unchanged.
AL-2050/2060: The LCD indicates "ERR."
Note that, this simulation must be executed with the OC cover closed.
∗ If the value is 0, float detection is not performed in normal jobs.
[Operation] (AL-2050/2060)
1) Initial display
41-06 OC FLOAT LEVEL
2) [OK]/[START] key
41-06 OC FLOAT LEVEL
EXECUTING...
[Function]
For the number of pixels between black markers on the SPF/RSFP scanning position saved in
"41-06: (OC cover float detection level adjustment)", if the number of pixels between the mark-
ers when processing float detection is less than the number of pixels set with this simulation, it
is judged as the float error.
When the set value of this simulation is "0," no float error occurs.
When this simulation is executed, the current set value is displayed.
Enter the adjustment value with [ ] [ ] key (or [Numeric] key for the AL-2050/2060), and press
[START] key. The setting is saved and the display is shifted to the sub code input standby menu.
Setting range: 0 – 99 (Copes with margin 0 – 99 pixels.)
Default: 30 (30 pixels)
[Operation]
The operation is similar to simulation 9-04.
AL-2020/2035/2040/2050/2060 SIMULATION, TROUBLE CODES 10 - 15
Details of function/operation
<Canceling - when [Clear]/[Clear All] key is pressed->
After canceling, the machine goes into the sub code entry
standby mode.
0
THE JOB IS BEING
CANCELED.
3) When the level is acquired:
41-06 OC FLOAT LEVEL
3) When the level is not acquired:
41-06 OC FLOAT LEVEL
**** OK
**** ERR

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Al-2050Al-2060Al-2035Al-2040

Table of Contents