Ike Negotiation Failed Because No Ike Proposals Or Ike Keychains Are Referenced Correctly - HP 5920 Series Configuration Manual

Hide thumbs Also See for 5920 Series:
Table of Contents

Advertisement

2.
When IKE event debugging and packet debugging are enabled, the following messages appear:
IKE event debugging message:
The attributes are unacceptable.
IKE packet debugging message:
Construct notification packet: NO_PROPOSAL_CHOSEN.
Analysis
Certain IKE proposal settings are incorrect.
Solution
1.
Examine the IKE proposal configuration to see whether the two ends have matching IKE proposals.
2.
Modify the IKE proposal configuration to make sure the two ends have matching IKE proposals.
IKE negotiation failed because no IKE proposals or IKE
keychains are referenced correctly
Symptom
1.
The IKE SA is in Unknown state.
<Sysname> display ike sa
Connection-ID
------------------------------------------------------------------
1
Flags:
RD--READY RL--REPLACED FD-FADING
2.
The following IKE event debugging or packet debugging message appeared:
IKE event debugging message:
Notification PAYLOAD_MALFORMED is received.
IKE packet debugging message:
Construct notification packet: PAYLOAD_MALFORMED.
Analysis
If the following debugging information appeared, the matched IKE profile is not referencing the
matched IKE proposal:
Failed to find proposal 1 in profile profile1.
If the following debugging information appeared, the matched IKE profile is not referencing the
matched IKE keychain:
Failed to find keychain keychain1 in profile profile1.
Solution
Verify that the matched IKE proposal (IKE proposal 1 in this debugging message example) is
referenced by the IKE profile (IKE profile 1 in the example).
Verify that the matched IKE keychain (IKE keychain 1 in this debugging message example) is
referenced by the IKE profile (IKE profile 1 in the example).
Remote
192.168.222.5
265
Flag
DOI
Unknown
IPSEC