11) Check the front intermediate motor harness
and the rear intermediate motor harness for continuity.
10 ohms or less? Go to the next step.
Open? Replace as necessary.
Check Motor Resistance at Motor.
12) Make sure that the pins are seated properly on 10a. Disconnect 10a from 9b if necessary.
Refer to figure 11 on page 10.
13) Measure resistance across pin 1 (thick red wire) and pin 2 (thick black wire) on 10a. See gure 29.
50 ohms or less but not shorted?
(NOTE: Can be as low as 0.2 ohms). Replace the controller.
Out of that range? Replace the drivetrain assembly.

BEEP CODE #9 - CONTROLLER FAULT

This Beep Code means that the controller has an internal fault.
1) Remove the key from the key switch and allow the controller to cool down. If the code continues, then replace the
controller.
Figure 29. Connector 10a
MEASURE RESISTANCE
Buzzaround XL_SG_REVA_100711
18