Vent Location; Vent Configurations - Travis Industries 616 GSR Green Smart Owner's Manual

Table of Contents

Advertisement

Vent Location

An Exhaust Restrictor is built into the appliance to adjust the flow rate of exhaust gases. This
ensures proper combustion for all vent configurations. Depending upon the vent configuration, you
may be required to adjust the restrictor position. See "Exhaust Restrictor" on page 15.

Vent Configurations

Inlet & Exhaust Re-Line
(recommended)
Exhaust
Z.C. (Metal) Wood-Burning Fireplace
NOTE: You may use either re-line configuration with a masonry or zero-clearance fireplace.
© Travis Industries
Finalizing the Installation
Direct Vent Cap
6-5/8" to 3" & 4" Colinear
Adapter & Flashing
Inlet
Recommended Block-Off
Plate (non-combustible
metal and/or insulation).
Prevents odors from
chimney entering room.
4051112
Exhaust Only Re-Line
(not recommended)
Exhaust
Any cracks or
damage inside the
chimney must be
repaired.
A block-off plate must
seal the intake to the
chimney space. This
way air is drawn down
the chimney for
combustion air.
Block-Off Plate
(non-combustible
materials)
Inlet
Masonry Fireplace
19
100-01271_000