List print mode (9S): The procedure varies depending on the code.
[9][START]
(Code)
[POWER]
101: Adjustment mode (05)
102: Setting mode (08)
(Code)
103: PM support mode
104: Stored information of pixel counter (toner cartridge reference)
105: Stored information of pixel counter (service technician reference)
106: Error history (Maximum 1000 items)
107: Error history (Latest 80 items)
PM support mode (6S):
[6][START]
[POWER]
2: PM Support Screen
Firmware update mode (89): Refer to "6. FIRMWARE UPDATING".
Normal
[0][1]
Control panel
Warming up
check mode
Ready
[POWER]
OFF
*1
To user
*1 Turn OFF the power after using the self-diagnosis mode, and leave the equipment to the user.
June 2005 © TOSHIBA TEC
[START]
[Digital keys]
Key in the first
code to be printed
(Code)
[START]
(Operation started)
[POWER]
ON
[0][3]
[0][4]
[0][5]
Test print
Adjustment
Test mode
mode
mode
State transition diagram of self-diagnosis modes
Fig. 2-1
e-STUDIO281c/351c/451c ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 25
[START]
[Digital keys]
Key in the last
List starts to
code to be printed
be printed
[POWER] OFF/ON
(Exit)
[0][8]
[9][START]
List print
PM support
Setting
mode
mode
[START]
[POWER]
OFF/ON
(Exit)
[6][START]
[8][9]
Firmware
update mode
mode