* The larger the adjustment value is, the wider the blank area at the right side becomes
(approx. 0.04 mm/step).
[H] Bottom margin
While pressing [0] and [5] simultaneously, turn the power ON. → (Adjustment Mode)
(1)
(2)
Open platen cover or RADF.
Press the [FAX] → [START] to make a copy at the mode of A3/LD, 100%, Black, Text/Photo and
(3)
lower drawer.
(4)
Measure the blank area G at the trailing edge of the copied image.
(5)
Check if the blank area G is within the range of 2±0.5 mm.
(6)
If not, use the following procedure to change values and repeat the steps 2. to 4. above.
<Procedure>
(Adjustment Mode) → (Key in the code [433]) → [START]
→ (Key in value (acceptable values: 0 to 255))
→ [ENTER] or [INTERRUPT] (stored in memory)
→ ("100% A" is displayed.)
* The larger the adjustment value is, the wider the blank area at the trailing edge becomes
(approx. 0.04 mm/step).
e-STUDIO281c/351c/451c ADJUSTMENT
Feeding direction
F
Fig.3-8
Feeding direction
G
Fig.3-9
3 - 18
June 2005 © TOSHIBA TEC