Drive System Related Service Call - Toshiba e-STUDIO351c Service Handbook

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO351c:
Table of Contents

Advertisement

5.1.8

Drive system related service call

[C010] Main motor abnormality
Is the main motor working? (Perform the output check: 03-101/151)
|
NO
|
|
|
|
|
|
|
|
YES
1) Check if the PLL lock signal CN336-8 pin output from the LGC board is always level "L".
2) Check if the voltage supplied to the ASIC input terminal IC40-152 pin is always "L".
3) Replace the LGC board.
[C020] Developer motor abnormality
Is the developer unit motor working? (Perform the output check: 03-112/162)
|
NO
|
|
|
|
|
|
|
|
YES
1) Check if the PLL lock signal CN337-B6 pin output from the LGC board is always level "L".
2) Check if the voltage supplied to the ASIC input terminal IC40-150 pin is always "L".
3) Replace the LGC board.
[C030] Transport motor abnormality
Is the transport motor working? (Perform the output check: 03-123/173)
|
NO
|
|
|
|
|
|
|
|
YES
1) Check if the PLL lock signal CN337-A7 pin output from the LGC board is always level "L".
2) Check if the voltage supplied to the ASIC input terminal IC40-149 pin is always "L".
3) Replace the LGC board.
e-STUDIO281c/351c/451c TROUBLESHOOTING
1) Check if the connector J581 of the main motor is disconnected.
2) Check if the connector CN336 on the LGC board is disconnected.
3) Check if the connector pins are disconnected or the harnesses are open
circuited.
4) Check if the conductor patterns on the main motor board and LGC board
are short circuited or open circuited.
5) Replace the main motor.
6) Replace the LGC board.
1) Check if the connector J578 of the developer motor is disconnected.
2) Check if the connector CN337 on the LGC board is disconnected.
3) Check if the connector pins are disconnected or the harnesses are open
circuited.
4) Check if the conductor patterns on the developer motor board and LGC
board are short circuited or open circuited.
5) Replace the developer motor.
6) Replace the LGC board.
1) Check if the connector J582 of the transport motor is disconnected.
2) Check if the connector CN337 on the LGC board is disconnected.
3) Check if the connector pins are disconnected or the harnesses are open
circuited.
4) Check if the conductor patterns on the transport motor board and LGC
board are short circuited or open circuited.
5) Replace the transport motor.
6) Replace the LGC board.
5 - 52
June 2005 © TOSHIBA TEC

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio281cE-studio451c

Table of Contents