This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for
use with other gases, unless a certified kit is used.
Read this complete manual before beginning installation.
These instructions must be kept with the unit for future reference.
WARNING: If the information in these instructions is not followed
exactly, a fire or explosion may result causing property damage,
personal injury or loss of life.
Warning: Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal injury or loss of
life. Refer to this manual. Installation and service must be performed
by a qualified installer, service agency or the gas supplier.
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
What To Do If You Smell Gas
Do not try to light any appliance.
Extinguish any open flame.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbour's phone.
If you can not reach your gas supplier, call the fire department.
A Division of R-Co. Inc.
2340 Logan Avenue
Winnipeg, Manitoba, Canada R2R 2V3
Ph: (204) 632-1962

Installation Instructions

Model Number VFI25
Gas Fired Room Heater
Model VFI25
Listed Certified for USA. and Canada
Minimum Fireplace Opening Required: 24"W x 17-1/2"H x 16"D
Certified to: ANSI Z21.88-2009, CSA 2.33-2009
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
FOR YOUR SAFETY
Printed in Canada
Insert
August 18, 2010
Part # 25VFI-MAN
WARNING: The VFI25 Fireplace
Insert was designed for installation
in a solid fuel fireplace that has
been installed in accordance with
national, provincial/state and local
building codes and is constructed
of noncombustible materials. Do not
remove any refractory materials
from any masonry solid fuel
fireplace.
The VFI25 Fireplace Insert was
designed for installation in a zero
clearance type listed solid fuel burning
factory built fireplace. It may be
necessary to remove the damper plate,
refractory liners, log grates, glass door,
and screen rails/mesh. Removal of the
smoke baffle is necessary in most
cases.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VFI25 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kingsman VFI25

  • Page 1: Installation Instructions

    Do not store or use gasoline or other flammable vapors and liquids in the fireplace. vicinity of this or any other appliance. The VFI25 Fireplace Insert was designed for installation in a zero What To Do If You Smell Gas clearance type listed solid fuel burning Do not try to light any appliance.
  • Page 2: Pre-Installation Questions And Answers

    Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone stove paint. This paint dries quickly in 15-20 minutes when first applied at the factory. However, due to the high temperature silicone components, the paint will cure when heat is applied to the appliance as it is first used.
  • Page 3: Table Of Contents

    VFI25/VFI30 Conversion Kit Instructions – Part A………………………. Gas Conversion for Top Convertible Pilot (Series 019065X) – Part B… Gas Conversion for Modulator – Part C………………………………….. Field Conversion for ZDV6000 - VFI25 - VFI30…………………………. Combustion Air………………………………………………………………. Unit Operation & Check-out………………………………………………... Check-out……………………………………………………………………..
  • Page 4: Mobile Home/Manufactured Housing Installation

    Mobile Home/Manufactured Housing Installation This Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installation, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.
  • Page 5: Warnings, Installations, And Operations

    Warnings, Installations, and Operations Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CGA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1 when installed in the United States. This appliance, when installed, must be electrically connected and grounded in accordance with local codes, or in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or with the national Electrical Code;...
  • Page 6: Warnings, Installations, And Operations

    • Gas fired appliances may be used only for supplemental heat and/or decorative purposes and under no circumstances shall they provide a primary heat source. • If the factory-built fireplace has no gas access hole(s) provided, an access hole of 1.5in [37.5mm] or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship like manner.
  • Page 7: Unit Identification

    1. UNIT IDENTIFICATION 4. CLEARANCES This fireplace was designed for installation in a solid fuel Vented Fireplace Insert (VFI30N or VFI30LP). This unit fireplace that has been installed in is offered with variable speed fan and variable gas input. accordance with National, Provincial/State and Local building codes and is constructed of non-combustible materials.
  • Page 8: Gas Piping

    Thermostat Connection and On/Off Switch Millivolt VENT LENGTH (4” Diameter Vent) Thermostat ( optional but recommended). All controls are connected directly to the gas valve and the circuit is Vertical (rise) Horizontal (run) made between: l0 ft - 3.1m 0 ft - 0.0 m •...
  • Page 9 When installing the venting please take note of the following: 1. A masonry chimney or other approved venting system must be clean and inspected for any damage which might make it unsafe. Chimney must be constructed of non combustible material. 2.
  • Page 10: Installation

    8. INSTALLATION NOTE: INSTALLATION AND REPAIR SHOULD BE PERFORMED BY A QUALIFIED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MA Y BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, ETC. IT IS IMPERATIVE THAT THE CONTROL COMPARTMENT, BURNING AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.
  • Page 11: Logc5 Or Logf5 Placement Guide

    LOGC5 OR LOGF5 PLACEMENT GUIDE C5 or F5 Parts Burner Step 1: Break ember wool into thumbnail Step 2: Place Log #1 on burner as shown size pieces. Place glowing embers evenly on and pull forward to the grate bars. Place log to the front burner tube as shown.
  • Page 12: Logc6 Placement Guidelines

    LOGC6 PLACEMENT GUIDELINES Log C6 Parts List Burner Step 1: Place Log #1 on rear log holder, cen- Step 2: Place Log #3 onto the left notch of ter it, and push back. Place Log #2 against Log #1 and against the left grate bar as the left burner mount and back against the shown.
  • Page 13: Burner System Maintenance

    It is recommended to turn on the unit at least once a month and inspect the flame pattern to ensure there are no problems with the burner tube. The pilot flame should also be inspected monthly to ensure proper operation. Flame should appear similar to the above picture. VFI25 Conversion Kit Instructions – PART A Kit Number Description...
  • Page 14: Vfi25/Vfi30 Conversion Kit Instructions - Part A

    VFI25/VFI30 Conversion Kit Instructions – PART A Caution : The gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion. WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's instructions and all applicable codes and requirements of the authority having jurisdiction.
  • Page 15: Gas Conversion For Top Convertible Pilot (Series 019065X) - Part B

    Gas Conversion for Top Convertible Pilot (Series 019065X) – PART B Instructions for converting SIT 190 series pilot burner injection from NG to LPG and from NG to LPG only. This information should be considered as supplemental to the Appliance Manufacturer’s Instructions. WARNING: The installation of this conversion kit must only be undertaken by a qualified and certified gas appliance installer.
  • Page 16: Gas Conversion For Modulator - Part C

    Gas Conversion for Modulator – PART C...
  • Page 17: Field Conversion For Zdv6000 - Vfi25 - Vfi30

    Field Conversion for ZDV6000 - VFI25 - VFI30 Warning: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. C6GEK: ZDV6000 Conversion C30GEK: VFI25 &...
  • Page 18: Combustion Air

    9. COMBUSTION AIR Indoor combustion air must conform to the requirements of the applicable code: Canada Installation Code CAN/CGA-B149.1 or (USA.) National Fuel Gas Code ANSI-Z223.1 In homes of normal construction, sufficient combustion air can usually be obtained by air infiltration. The fireplace insert must be installed in area that is free of excessive dust and dirt and where ventilation is sufficient to provide proper combustion of gas, proper venting and the...
  • Page 19: Check-Out

    Sequence of operation: Pressure ranges are as listed below: 1. Turn On/Off switch ( or thermostat) to the on (call for heat) position. Gas Supply Pressure (inches w.c.) Main burner lights. Normal If blower variable speed switch is in the Natural Gas “On”...
  • Page 20: Maintenance

    (c) Logs 13. MAINTENANCE CAUTION: The logs can stay hot for several CAUTION: Label all wires prior to hours after the fireplace is shut off. Serious disconnection when servicing controls. Wiring burns could result. It is recommended that the errors can cause improper and dangerous fireplace be turned off for several hours before operation.
  • Page 21 1/32’ to all four sides of the frame and insert the glass with a new gasket. The door frame should be Warning The appliance area must be kept on a flat surface with a small amount of weight clear and free from combustible materials, pressing the glass into the silicon.
  • Page 22: Surround And Brass Trim Assembly Instructions

    14. Surround and Brass Trim Assembly Instructions (Three Piece Surround & Picture Frame) Before attaching surround assembly, check operation of insert and installation of draft hood and chimney liner. To assemble surround attach panel (A), (B), (C), and (A1) if Picture Frame was purchased) with bolts (10/24) and star lock nuts, if optional brass panel kit was purchased install at this time over the surround kit and tighten the bolts to secure all panels.
  • Page 23: Surround Kit Parts List

    15. SURROUND KIT PARTS LIST Ref. Surround Small Surround Large Picture Frame Part Number Part Number Part Number Description Quantity 3000-301 3000-311 3000-320 Top Panel 3000-302 3000-312 3000-321 Side Panel Left 1 3000-303 3000-313 3000-322 Top Panel Right 1 3000-323 Bottom Panel 3000-304 3000-314...
  • Page 24: Wiring Diagram - For Sit Valve System

    17. WIRING DIAGRAM - FOR SIT VALVE SYSTEM For units with serial number greater than 13930, see 820639 - 820640 systems. SPILL SAFETY SWITCH - Wiring Diagram Wiring diagram with Non Thermocouple Thermocouple SIT 820-639 and 820-640 True Millivolt Systems This System does not have a thermocouple SIT 820633,820634 Valves...
  • Page 25: Accessory List

    V25T2436C Trim Kit - Chrome V25T2436P Trim Kit - Polish Brass (Size 24 13/16” High x 36 3/16” Wide) V25S2640B Surround Large Deluxe - Black VFI25 V25T2640A Trim Kit - Antique Brass V25T2640C Trim Kit - Chrome V25T2640P Trim Kit - Polish Brass (Size 26 13/16”...
  • Page 26: Accessory List

    Log Sets (Required for each Insert) LOGC5 Log Set - Four Piece Cast Split Oak LOGF5 Log Set - Four Piece Fibre Split Oak LOGC6 Log Set - Four Piece Cast Split Oak c/w Glowing Ember Rocks Optional Accessories V25P2738A Panel Large Kit - Antique Brass (For use on V25S2738B) V25P2738C Panel Large Kit - Chrome...
  • Page 27: Replacement Parts

    21. REPLACEMENT PARTS FOR VFI25 Valve System Parts - S.I. T . SYSTEM #1 Old SIT System (If Serial Number is LESS than 25727) Part Number Description 1000-P136WR Thermopile GOAI-524 1001-P035SI Electrode Sparker 915.035 SIT 1001-P129SI Thermocouple 290.129 SIT unified 1001-P157SI Orifice Pilot LP 977.157 SIT...
  • Page 28: Replacement Parts

    Gasket (1-5/8 x 1/2) 3000-959 Thermalcord (for Door) C30-GEK Grate & Ember Plate kit for C6 Log Set Field Conversion c/w Ember Plates & Grate Bars (4 each) (VFI25, VFI30) Conversion Kit (SIT Valve only) 25VFI-CKLP LP Conversion Kit 25VFI-CKNG...
  • Page 29: Lighting Instructions

    22. MILLIVOLT LIGHTING INSTRUCTIONS Recommended Maximum Lead Length (Double Wire) When Using Wall Switch or Thermostat Wire Size Max. Length 14 GA. 100 FT. 16 GA. 64 FT. 18 GA. 40 FT. 20 GA. 25 FT. 22 GA. 16 FT. Pilot Burner Adjustment CAUTION: DO NOT 1.Adjust pilot screw to provide...
  • Page 30: Kingsman Industries Warranty

    During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer.