Kingsman MDV30 Installation Instructions Manual

Mdv31 series, mdv39 series multi-sided direct vent decorative gas fireplace

Advertisement

Installation Instructions

Certified to: ANSI Z21.50-1996/CGA 2.22-M96, CAN/CGA 2.17-M91, CSA P.4.1-02
Model MDV31 Series - MDVR31N, MDVR31LP, MDVL31N, MDVL31LP
Model MDV39 Series - MDVR39N, MDVL39N Conversion only
Certified to: ANSI Z21.50-2002/CSA 2.22-2002 Vented Gas Fireplace, CSA P.4.1-02
"Multi-Sided Direct Vent"
Decorative Gas Fireplace
Read this complete manual before beginning installation.
These instructions must be kept with the unit for future reference.
Do not store or use gasoline or other flammable vapors and liquids in the
Immediately call your gas supplier from a neighbour's phone.
If you can not reach your gas supplier, call the fire department.
Warning: Improper installation, alteration, service or maintenance can cause property damage, personal
injury or loss of life. Refer to this manual. Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
Listed Certified for USA. and Canada
Models MDV30/38

FOR YOUR SAFETY

vicinity of this or any other appliance.
What To Do If You Smell Gas
Do not try to light any appliance.
Extinguish any open flame.
Do not touch any electrical switch.
Do not use any phone in your building.
A Division of R-Co. Inc.
2340 Logan Avenue
Winnipeg, Manitoba, Canada R2R 2V3
Ph: (204) 632-1962
Printed in Canada June 22, 2009 Part #3100-MAN

Advertisement

Table of Contents
loading

Summary of Contents for Kingsman MDV30

  • Page 1: Installation Instructions

    Installation Instructions Listed Certified for USA. and Canada Models MDV30/38 Certified to: ANSI Z21.50-1996/CGA 2.22-M96, CAN/CGA 2.17-M91, CSA P.4.1-02 Model MDV31 Series - MDVR31N, MDVR31LP, MDVL31N, MDVL31LP Model MDV39 Series - MDVR39N, MDVL39N Conversion only Certified to: ANSI Z21.50-2002/CSA 2.22-2002 Vented Gas Fireplace, CSA P.4.1-02 “Multi-Sided Direct Vent”...
  • Page 2 PRE-INSTALLATION QUESTIONS and ANSWERS Why does my fireplace or stove give off odour? It is normal for your fireplace to give off some odour. This is due to the curing of the paint, adhesives, silicones and any undetected oil from the manufacturing process as well as the finishing materials used with the installations (e.g.
  • Page 3: Table Of Contents

    Table of Contents Unit Dimensions ......... . . 2 Locating Your Appliance .
  • Page 4: Unit Dimensions

    Unit Dimensions - With Louvers SEE - THRU UNIT 41.062" CORNER UNIT R/H PENINSULA UNIT 38.062" 38.062" .50" .50" TOP VIEW TOP VIEW 20.687" 23.687" SIDE VIEW 36.125" VIEW 16.125" 16.125" REAR 32.625" 31.875" VIEW 29.75" 15.50" ▼ ▼ 21.687" 36.062"...
  • Page 5: Locating Your Appliance

    Locating your Appliance...
  • Page 6: Corner Installations - Louvered Unit Only

    Corner L/H & R/H Installation Instructions - Louvered Unit Only FRAMING DETAIL FRAMING THROUGH Combustible WALL Using 2x4s frame to local building codes. DO NOT install against a Vapour Barrier or Exposed 11.0" Insulation. Framing measurements have been adjusted to accommodate a 1/2"...
  • Page 7 FIGURE 3 SIDE BRICK PANEL BRICK PANEL INSTALLATION 1. Insert side Brick panel into place, using Brick retaining clip position and screw to top of firebox. BRICK 2. Install rear Brick panel, brick CLIP retaining clip located at top. REAR BRICK PANEL NOTE! NOTE!
  • Page 8: See-Thru Installations - Louvered Unit Only

    See-Thru Installation Instructions - Louvered Unit Only FRAMING Using 2x4s frame to local building codes. DO NOT install against a Vapour Barrier or Exposed Insulation. Framing measurements have been adjusted to accommodate a 1/2" thick finished wall. FIGURE 1 FRAMING DETAIL Combustible materials may be installed flush with top HORIZONTAL RUN of standoffs and sides of fireplace.
  • Page 9 NOTE! This UNIT is not FACING MATERIAL INSTALLATION Load Bearing Facing material. Example DRYWALL may be installed Flush with top of Fireplace. Side facing to be installed to standoffs only. DRYWALL Gyprock Gyprock...
  • Page 10: See Through With Cvck - Dimensions & Enclosures

    See Through With CVCK -Dimensions- Note: When CVCK is used, a CVCK Kit must be installed on Both sides of the unit. See Through With CVCK -Enclosures-...
  • Page 11: See Through With Cvck - Installation

    See-Thru With CVCK Installation Framing (The following method assumes that framing is in place before the unit is installed.) Using 2x4’s, frame to local building codes. DO NOT install against a Vapor Barrier or Exposed Insulation. Framing measurements have been adjusted to accommodate a ½” thick finished wall. Combustible materials may be installed flush with the top and sides of the installed CVCK Kits.(See Page 10, “Framing and Facing Requirements.) It is not necessary to install a hearth with this fireplace system.
  • Page 12: See Through Framing & Facing Requirements

    See Through - FRAMING & FACING REQUIREMENTS MDV31 with CVCK (Clean View Circulating Kit) Note: When CVCK is used, a CVCK Kit must be installed on Both sides of the unit. MDV31 with MQ36SWF Surround...
  • Page 13: How To Install Cvck

    MDV31 - How to Install Clean View Kit (Z36 CVCK) Caution: When using CVCK do not install Louver Assembly. Install optional Fan Kit (See Fan instructions). Fold the tall 8” standoffs up into position and mount them with the supplied screws. Bend the center tab on the four [4] Nailing Tabs 90°...
  • Page 14: Mqsw Wall Mount Surround - Dimensions & Installation

    MQSW Wall Mount Surround Dimensions MQSW Wall Mount Surround Dimensions Installation of MQ Wall Mount Surrounds Installation of Wall Mount Surrounds 1. Set Surround Lip on CVCK Ledge and ensure that it is securely in place. 2. Swing the upper portion of the Surround so that the Surround Ledge is resting on top of the CVCK Deflector Lip. 3.
  • Page 15: Peninsula Installations - Louvered Unit Only

    Peninsula Installation Instructions - Louvered Unit Only FRAMING FRAMING DETAIL HORIZONTAL RUN Using 2x4s frame to local building codes. WITH MIN. VERTICAL RUN DO NOT install against a Vapour Barrier or Exposed Insulation. Framing measurements have been adjusted to accommodate a 1/2" thick finished wall. FIGURE 1 Combustible materials may be installed flush with top 11.0"...
  • Page 16 FACING MATERIAL INSTALLATION Facing material. Example DRYWALL may be installed Flush with top of DRYWALL Fireplace. Side facing to be installed to standoffs only.
  • Page 17: Low Profile Enclosures - Louvered Unit Only

    Low Profile Enclosures - Louvered Unit Only NOTE NOTE INSULATION SLEEVE MUST WITH USING DURA-VENT COVER 7.0" FLEX PIPE FROM PIPE AND ADAPTER MINIMUM FIREPLACE UP AND TO WALL. HEIGHT OF 52.0" MUST BE SLEEVE FOR LOW PROFILE MAINTAINED FOR PROPER ENCLOSURES MAXIMUM 34.0".
  • Page 18: Clearances Mdv31 Mantels & Surrounds

    Clearances – MDV31 – Mantels & Surrounds Clearance to Combustibles ) t i c i t Ceiling (from bottom of fireplace) 60 inches /152.4cm Top Framing from Standoff 0 inches /0mm Louvered Units Only Top of 90° Bend No Sleeve, in Enclosure over 4 inches /102mm 52”...
  • Page 20: Installation & Operation

    Installation and Operation Installation Regulations called to inspect this appliance annually. Make it a practice to have all your gas appliances checked annually. This gas appliance must be installed by a qualified installer in accor- 6. Control compartments, burners and air passages in this appliance dance with local building codes, or in the absence of local codes, with the current CAN/CGA-B149.1 or .2 Installation Code (in Canada) or should be kept clean and free of dust and lint.
  • Page 21: Installation Requirements For The Commonwealth Of Massachusetts

    Installation Requirements for the Commonwealth of Massachusetts In the Commonwealth of Massachusetts, the installer or service agent shall be a plumber or gas fitter licensed by the Commonwealth. When installed in the Commonwealth of Massachusetts or where applicable codes; the unit shall be installed with a CO detector per the requirements listed below.
  • Page 22: Fan Kit Installation

    Fan Kit Installation SUGGESTED LOCATION FOR 120V SUGGESTED LOCATION FOR 120V JUNCTION BOX FOR FAN KIT POWER CABLE THERMODISC BOTTOM OF FIREBOX GAS INLET WALL MOUNTED VARIABLE SPEED L/H FIREPLACE SHOWN CONTROL 1. To install fan slide key hole mounts onto both #8 screws, located rear bottom bracket.
  • Page 23: Door And Grill Installation

    Door and Grill Installation DOOR ASSEMBLY To install all Doors, first install bottom screws into Fireplace. Set slots in bottom of Doors onto screws, slide top of Door onto Fireplace and insert top screws. Tighten bottom and top screws so that they are snug.
  • Page 24: Bay Window Instructions

    MUST REMAIN INSTALLED ON FIREPLACE. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY CAUSE INJURY. THE BAY WINDOW IS NOT TO BE USED WITH TEMPERED GLASS MODEL MDV30 SERIES Before installing Bay window spread crushed rock in bottom of Bay window pan. Sprinkle Vermiculite on top of crushed rock.
  • Page 25: Metal Or Brick Panel Installation

    Shown FIGURE 5 VIEW LOGF38 - LOG INSTALLATION The KINGSMAN Log set has been numbered for ease of installation. Crushed Rock and Glowing Ember Installation 1. Apply Crushed Rock to bottom pan and to Grate area. Do Not cover Burner with Crushed Rock.
  • Page 26: Log Placement

    Log Tabs Step (1) If using the MVF40 chassis, omit this step (go to step 2). If using MDV30 or MDV38, break glowing embers into thumbnail size and place along the perimeter of the burner. Do not place on middle burner (as illustrated).
  • Page 27 LOGC31 Placement Guidelines for Model MDV31/39 TAB 3a TAB 3b TAB 4a ❶ ❹ FLAT EMBERS TAB 4b AREA NOTCH ❷ ❺ ROCK EMBER PLATES ❼ ❻ ❸ NOTCH GRATE TAB 2a Photo 1 Photo 2 ❶ ❷ TAB 2a GRATE Step (1) Place notch area of Log #1 up against pilot assembly.
  • Page 28 LOGC31 Placement Guidelines for Model MDV31/39 (continued) ❹ ❺ GRATE Step (4) Locate the two mounting holes on the bottom Log #4 and Step (5) Place ‘V’ area of Log#5 onto grate bar and rest log onto flat area position them onto Tabs 4a - 4b. of Log #2.
  • Page 29: Mqrsp7 Rock Support Platform & Mqrock1

    MQRSP7 Rock Support Platform (MDV31) and MQROCK1 MQRSP7 Remove grate bars, log bracket, and bend down all the ember plate tabs. Place MQRSP7 Rock support platform Step 1: Place rocks #4 into position as into place around the burner as shown. shown.
  • Page 30 MQRSP7 Rock Support Platform and MQROCK1 Step 5: Place rocks #3 and #6 into Step 4: Place rocks #1 into position as position as shown. shown. Step 6: Place rocks #3 into position as Step 7: Place rock #1 into position as shown.
  • Page 31: Brick Panel Installation

    Brick Panel Installation REMOVAL OF METAL PANEL BEFORE INSTALLING REAR BRICK PANEL 1. Locate 2 screws on bottom rear of unit holding metal panel to firebox bottom, remove the 2 screws and discard. 2. Hold metal panel by the bottom and pull forward and down at the same time. This will release the panel from the holder at the top of the unit.
  • Page 32: Burner Replacement

    Burner and Valve Removal Instructions for Models MDV31/39 BURNER REMOVAL AND REPLACEMENT 1. Turn OFF the Gas and Electric Power before servicing the Fireplace. 2. Remove doors. Remove end, back or side bricks, this depends on type of Fireplace installation. Remove all Crushed Rock and Glowing Embers.
  • Page 33: Millivolt Lighting Instructions

    Millivolt Lighting Instructions Recommended Maximum Lead Length (Double Wire) When Using Wall Switch or Thermostat Wire Size Max. Length 14 GA. 100 FT. 16 GA. 64 FT. 18 GA. 40 FT. 20 GA. 25 FT. 22 GA. 16 FT. CAUTION: DO NOT Pilot Burner Adjustment 1.
  • Page 34: Gas Line Installation

    REPLACEMENT GLASS FOR BOTH DIRECT VENT UNITS densation, which is normal, forms on the inside of the glass and causes Model MDV30 or MDV31 Series can use either tempered glass or dust, lint etc. to cling to the glass surface. Also, initial paint curing can Robax ceramic or coated Neaoceram glass.
  • Page 35: Vent Termination

    The gas fireplace is approved to be vented either through the side wall or vertically through the roof. E - Clearance to unventilated soffit 12 inches (30cm) minimum. This appliance is approved with Kingsman flex vent system and also F - Clearance under veranda, porch, deck or balcony 12 inches (30cm) approved for use with Simpson Duravent Direct Vent System (model minimum.
  • Page 36: General Vent Installation

    General Vent Installation Information This gas appliance is approved to be vented either through the FRAMING DIMENSION side wall or vertically through the roof. Only Kingsman venting Combustible Wall kits and components specifically approved and LABELED for Cut a 11” hole through exterior wall and frame as shown below.
  • Page 37: Horizontal Venting Routes

    Horizontal Venting Routes Venting Routes And Components How To Use The Vent Table Determine the height of the system and the Since it is important that the vent system maintain its number of bends required. balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent Having determined the vertical distance, configurations apply and must be strictly adhered to.
  • Page 38 20 FEET FIGURE 2 SUPPORT STRAPS EVERY 2 FEET 2.5" rise per ft. for horizontal runs with min. vertical from 7 FEET Fireplace. SIDE VIEW 35.0" Important Minimum clearances of For installations other than Low Profile flue pipe to combustibles. Enclosures, top of horizontal with no Vertical runs 1.0".
  • Page 39: Vertical Venting

    Vertical Venting Venting Straight Up Through Roof Roof Flashing 1. An Attic Insulation Shield must be installed where the vent passes from a Ensure that you have the proper roof flashing by checking your roof lower living space into an attic space where the chimney is not enclosed. It pitch using a level and two rulers, or by using a roof pitch card.
  • Page 40: Replacement Parts

    Replacement Parts 3800-173 3800-170 3800-171 BOTTOM BRICK PANELS NOT AVAILABLE 3800-127 3800-172 3800-138 3600-115 3800-130 3800-115 3800-304 3800-128 3800-129 EMBER-R EMBER-I 3800-303 ZIRC 1000-305 3800-312 1000-306 1000-306 Z1MT 3800-302 3800-132 3600-301 5000-P025WS 1000-150GE (RED) 3800-134 1000-150MP (BLACK) 1000-218...
  • Page 41 Replacement Parts (continued) For Models MDV31/39...
  • Page 42 Replacement Parts (continued) ZDVWT FDVHT FDVVT40 ZDV7FCL ZDV48GP ZDVSS ZDVRS ZDV4SS ZDV7SC ZDVST ZDVAAF ZDVAF2 ZDV7FC ZDVAF3 ZDV4FC ZDVAIS ZDVFK5 ZDVFK8 ZDVFK20 ZDVFS...
  • Page 43 MGSKCR Grill Kit See-Through -Chrome (Two Sets) DCHS Remote Control Heatshield MDV30 SERIES MULTI-SIDED DIRECT VENT FIREPLACE: Replacement Burner Assembly Listed for USA/Canada as a Decorative Appliance, Includes: Triple Burner, Up to 3800-BRNG Burner Assembly - Right, Natural Gas - For Model MDVR38N...
  • Page 44 Parts List for Models MDV31/39 Replacement Burner Assembly MDV31/39 SERIES MULTI-SIDED DIRECT VENT FIREPLACE: 3100-BRNG Burner Assembly - Right, Natural Gas - For Model MDVR31N Listed for USA/Canada as a Decorative Appliance, Includes: Triple Burner, Up to 3100-BRLP Burner Assembly - Right, Liquid Propane - For Model MDVR31LP Three Viewing Areas, Milli Volt Sit Valve Featuring less than 30 Sec Shut Down with Hi/Lo Adjustment, Wall Mount On/Off Switch, Ember Ash One Large Panel of 3100-BLNG...
  • Page 45: Kingsman Fireplace Venting

    Valve System Parts Kingsman Fireplace Venting (If Serial Number is LESS than: 31089 for MDV30 38322 for MVDV38) Catalog 1000-P136WR Thermopile GOAI-524 Number Description 1001-P035SI Electrode Sparker 915.035 SIT ZDVHSK Horizontal Vent Starter Kit - 3 FT Length 1001-P129SI Thermocouple 290.129 SIT unified...
  • Page 46: Trouble Shooting Guide

    Trouble Shooting The Gas Control System WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the “On” position. Problem Possible Causes Corrective Action Spark igniter will not light.
  • Page 47: Warranty

    During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer.

This manual is also suitable for:

Mdv38Mdvl31lpMdvr31nMdvr39nMdvr31lpMdvl39n ... Show all

Table of Contents