Field Conversion for ZDV6000 - VFI25 - VFI30

Warning: Failure to position the parts in accordance with these diagrams or failure to use only parts
specifically approved with this appliance may result in property damage or personal injury.
C6GEK: ZDV6000 Conversion
2 - Ember Plates
1 - Ember Plate Bridge
1 - Grate Assembly with 5/8" Bars
4 - 1/2" x 8-18 DT Screws
Tools Required: Drill, 1/8" Drill Bit, 1/4" Nut Driver Bit
Step 1: Remove existing grate bar by bending bar slightly forward and drill out rivets.
Step 2: Seal rivet holes with two supplied screws. (ZDV6000 ONLY)
Step 3: Center legs of Grate Bar on either side of burner support and fasten with supplied self drilling Screws. (Ref: 1)
Step 4: Place Ember Plates between burner tubes right and left of Burner.
NOTE: Raised flange of Ember Plates must be to back of Burner.
Step 5: Slide Ember Plate Bridge between Ember Plates. (Ref: 2)
C30GEK: VFI25 & VFI30 Conversion
2 - Ember Plates
1 - Ember Plate Bridge
1 - Grate Assembly with 1/2" Bars
2 - 1/2" x 8-18 DT Screws