Kingsman ZV3600 Installation Instructions Manual

Kingsman ZV3600 Installation Instructions Manual

Zero clearance vented gas fireplace

Advertisement

Installation Instructions

Model Numbers ZV3600, ZV4200
Zero Clearance Vented Gas Fireplace
CONSUMER: Retain this manual for future reference.
Read this complete manual before beginning installation.
These instructions must be kept with the unit for future reference.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property
damage, personal injury or loss of life. Refer to this manual. Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
If you can not reach your gas supplier, call the fire department.
For Propane Horizontal installations the venting must be a minimum of one foot vertical
off the flue before going horizontal.
Stock #'s: ZV3600N, ZV3600LP, ZV4200N, ZV4200LP are
Certified to: ANSI Z21.50b-2000, CSA 2.22b-2009
INSTALLER: Leave this manual with the appliance.

FOR YOUR SAFETY

What to Do If You Smell Gas
Do not try to light any appliance.
Extinguish any open flame.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbour's phone.
Printed in Canada October 19, 2009 36ZV-MAN
A Division of R-Co. Inc.
2340 Logan Avenue
Winnipeg, Manitoba, Canada R2R 2V3
Ph: (204) 632-1962

Advertisement

Table of Contents
loading

Summary of Contents for Kingsman ZV3600

  • Page 1: Installation Instructions

    Installation Instructions Model Numbers ZV3600, ZV4200 Zero Clearance Vented Gas Fireplace Stock #’s: ZV3600N, ZV3600LP, ZV4200N, ZV4200LP are Certified to: ANSI Z21.50b-2000, CSA 2.22b-2009 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. Read this complete manual before beginning installation.
  • Page 2 PRE-INSTALLATION QUESTIONS and ANSWERS Why does my fireplace or stove give off odour? It is normal for your fireplace to give off some odour. This is due to the curing of the paint, adhesives, silicones and any undetected oil from the manufacturing process as well as the finishing materials used with the installa- tions (e.g.
  • Page 3: Table Of Contents

    Millivolt system, lighting, & burner control ...........21 Vent Installation ...................23 Repair parts list ...................24 Kingsman Fireplace part numbers & specifications Options..............24 Kingsman Fireplace accessories............24 Kingsman Fireplace options ..............24 Valve System Parts................25 Trouble shooting the gas control system ..........26 Kingsman Industries Gas Fireplace – Limited Warranty......27...
  • Page 4: Warnings, Installations And Operations

    Warnings, Installations, and Operations Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CGA-B149.1 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1 when installed in the United States.
  • Page 5: Operations And Maintenance Instructions

    • Gas fired appliances may be used only for supplemental heat and/or decorative purposes and under no circumstances shall they provide a primary heat source. • This appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance. NOTE: It is recommended that a Carbon Monoxide (CO) Detector be installed in or near bedrooms and on all levels of your home.
  • Page 6: Locating Your Appliance

    Locating your Appliance (above or below grade) Installing with Top Vent A - Flat on a wall D - As a room divider When you install your fireplace as in position ‘B’, ‘D’ or ‘E’, a minimum B - Across the corner E - Flat on wall corner of 6 inches (153mm) clearance must be maintained from the perpen- C - As an island...
  • Page 7 Framing for your Gas Fireplace (cont.) FRAMING FOR ZV3600 4” B-Vent FRAMING FOR ZV4200 4” B-Vent...
  • Page 8 Hearth A hearth is not mandatory but is recommended for aesthetic pur- poses. We recommend a non-combustible hearth projecting out 12” (305mm) or more in front of the fireplace. Clearance to Combustibles Back (from Standoffs) 0 inches/0 mm Side (from standoffs) 0 inches/0 mm Floor 0 inches/0 mm...
  • Page 9: Installation Of Optional Fan Kit

    Installation of optional Fan Kit Electrical Services WARNING: Electrical Grounding Instructions. All optional fan kits are equipped with a 120V, 60 Hz This appliance is equipped with a three-pronged (grounding) plug for your protection against shock blower. hazard and should be plugged directly into a properly grounded three-prong receptacle.
  • Page 10: Installation Of Brick Panels

    Installing Brick Panels 1. Place rear brick panel up against the back of the firebox. 2. Loosen screw holding brick clip in position, swing clip up out of the way and place side brick up to rear brick and flush against side wall of firebox. Position clip over brick and tighten screw. 3.
  • Page 11: Gas Line Installation

    Gas Line Installation This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CAN/CGA - B149.1 or .2 installation codes for Gas Burning appliances and equipment in Canada and the National Fuel Gas Code ANSI Z223 in the U.S.A.
  • Page 12: General Glass Information

    It will be necessary to clean the glass periodically. During start- up, condensation, which is normal, forms on the inside of the Model Series ZV3600 or ZV4200 can use either tempered glass glass and causes dust, lint etc. to cling to the glass surface.
  • Page 13: Log Assembly And Fan Kit

    Log Assembly for Models ZV3600 and ZV4200 WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. Log Assembly (LOGC42) 7.Place right and left logs across front and back log.
  • Page 21: Millivolt System, Lighting, & Burner Control

    Millivolt System, Lighting, & Burner Control Recommended Maximum Lead Length (Double Wire) When Using Wall Switch or Thermostat Wire Size Max. Length 14 GA. 100 FT. 16 GA. 64 FT. 18 GA. 40 FT. 20 GA. 25 FT. 22 GA. 16 FT.
  • Page 22 For SIT 820633, 820634 Valves SPILL SAFETY SWITCH Wiring Diagram 820.639 and 820.640 True Millivolt Systems. This System does not have a thermocouple. For Units with serial numbers greater than 36350.
  • Page 23: Vent Installation

    Vent Instructions When installing with “B” Vent liquid fuel gas chimney install as per NOTE: A chimney venting this fireplace shall not vent any other appliance. “B” Vent Manufacturer Installation specifications. Offset vertical or vertical installations may be installed. This appliance may be vented into various types of applications: “A”...
  • Page 24: Repair Parts List

    Parts List PART NO. DESCRIPTION PART NO. DESCRIPTION ZV3600N Fireplace Decorative Top Flue (as above) NG, Child Safety Screens Tempered Glass, 21,000 BTU Z36CSS Child Safety Screen - 36” DV Fireplaces ZV3600LP Fireplace Decorative Top Flue (as above) LP, ZV4200N Fireplace Decorative Rated (as above) NG, Tempered Glass, 20,000 BTU Tempered Glass, 21,000 BTU...
  • Page 25: Valve System Parts

    Orifice Pilot LP 977.157 SIT 1001-P159SI Orifice Pilot NG 977.159 SIT Conversion Kit (SIT Valve only) 1001-P508SI HT Cable 16 3600ZV-CKLP LP Conversion Kit for ZV3600 1001-P633SI Valve Nova LP Hi/Lo 0820633 3600ZV-CKNG NG Conversion Kit for ZV3600 1001-P634SI Valve Nova NG Hi/Lo 0820634...
  • Page 26: Trouble Shooting The Gas Control System

    Trouble Shooting The Gas Control System WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the “On” position. Problem Possible Causes Corrective Action Spark igniter will not light.
  • Page 27: Kingsman Industries Gas Fireplace - Limited Warranty

    During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer.

This manual is also suitable for:

Zv4200

Table of Contents