Technical Specifications - Thinklogical T-4200 Product Manual

Sdi modules
Hide thumbs Also See for T-4200:
Table of Contents

Advertisement

2.9 Technical Specifications

Each Thinklogical VelocityKVM T-Series Module is designed to the following specifications:
Copper Connectors
Optical Cable
Optical Distance
Operating Temp
and Humidity
Dimensions
Weight
Supply Voltage
Power Consumption
Compliance
Warranty
T-Series SDI Modules, Rev. A
Transmitter:
Video
Serial Port
Fiber Connectors
Alarm
Receiver:
Video
Serial Port
Fiber Connectors
Alarm
Fiber Type:
50 or 62.5 micron, Multi-mode
Required (per module):
Up to 65 meters with Type OM1
Up to 350 meters with Type OM2
Up to 750 meters with Type OM3
Up to 1000 meters with Type OM4
Up to 40 kilometers with Single-Mode
0° to 50°C (32° to 122 °F), 5% to 95% RH, non-condensing
1.65" (41.91 mm) ± .039"; .1 mm
Height:
6.366" (161.70 mm)* ± .039"; .1 mm
Depth:
7.226" (183.54 mm) ± .039"; .1 mm
Width:
1 lb. (.454 kg)
100-240 VAC, 47-63 Hz, Universal AC power supply
10 Watts per module
Approvals for US, Canada, and European Union
Twelve months from date of purchase. Extended warranties available.
BNC (2)
DB9 Female
LC
Form C (3 contact)
BNC (2)
DB9 Male
LC
Form C (3 contact)
2 (Not supplied)
12
®
September 2011

Advertisement

Table of Contents
loading

Table of Contents