Thinklogical Velocitydvi-3 Product Manual

Single-link and dual-link fiber extension systems
Hide thumbs Also See for Velocitydvi-3:

Advertisement

Quick Links

Digital Video Extension System
Velocitydvi-3, Velocitydvi-33
Velocitydvi-6, Velocitydvi-63
Single-Link and Dual-Link Fiber Extension Systems
Thinklogical, LLC
®
100 Washington Street
Milford, Connecticut 06460 U.S.A.
Telephone: 1-203-647-8700
Fax: 1-203-783-9949
www.thinklogical.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Velocitydvi-3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Thinklogical Velocitydvi-3

  • Page 1 Digital Video Extension System Velocitydvi-3, Velocitydvi-33 Velocitydvi-6, Velocitydvi-63 Single-Link and Dual-Link Fiber Extension Systems Thinklogical, LLC ® 100 Washington Street Milford, Connecticut 06460 U.S.A. Telephone: 1-203-647-8700 Fax: 1-203-783-9949 www.thinklogical.com...
  • Page 2 Copyright © 2013. All rights reserved. Printed in the U.S.A. Thinklogical, LLC ® 100 Washington Street Milford, Connecticut 06460 U.S .A. Telephone 1-203-647-8700 All trademarks and service marks are the property of their respective owners. Subject: VelocityDVI-3, VelocityDVI-6, VelocityDVI-33 and VelocityDVI-63 Extender Product Manual Revision: G (May, 2013)
  • Page 3: Table Of Contents

    Table of Contents NTRODUCTION ....................... 3 1.1. C ......................... 3 ONTENTS 1.2. P ....................3 RODUCT VERVIEW 1.3. T DVI-3 -6 E ..............5 ELOCITY XTENDER ODELS 1.4. L ..................... 9 ASER NFORMATION YSTEM EATURES ....................9 2.1. G .................... 9 ENERAL YSTEM EATURES...
  • Page 4 6.1.4. F ........................37 6.2. P ....................... 37 RODUCT UPPORT 6.2.1. W ......................37 ARRANTY 6.2.2. R ............... 38 ETURN ERCHANDISE UTHORIZATION A: I PPENDIX NSTALLATION VERVIEW ................39 A.1 VEL-3 ........................39 A.2 VEL-3 A/V+ ........................ 40 A.3 VEL-6 ........................41 A.4 VEL-6 A/V+ ........................
  • Page 5: Introduction

    DB9F Adapter (ADP-000025-R) and DB9M Adapter (ADP-000019-R) • CD Product Manual • For VelocityDVI-3, Qty = 1 each. For VelocityDVI-33, Qty = 3 each For VelocityDVI-6, Qty = 1 each. For VelocityDVI-63, Qty = 3 each With A/V+ and A/N+ models With A/V+ models only 1.2.
  • Page 6 Velocitydvi Digital Video Extender-3 The Future of Access and Control The Future of Access and Control Transmitter: VEL-000M03-LCTX Receiver: VEL-000M03-LCRX Velocitydvi Digital Video Extender-6 The Future of Access and Control The Future of Access and Control Transmitter: VEL-000M06-LCTX Receiver: VEL-000M06-LCRX Velocitydvi Digital Video Extender-33 VEL-000M33-LCTX/RX...
  • Page 7: The Velocitydvi-3 And -6 Extender Models

    1.3. The VelocityDVI-3 and -6 Extender Models VEL-000S03-SCRX VELOCITY 3 DVI VIDEO EXTENDER, SINGLE LINK DVI, AUX DVI OUTPUT, DDC, SINGLE MODE, SC/APC VEL-000S03-SCTX VELOCITY 3 DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI OUTPUT, DDC, SINGLE MODE, SC/APC VOP-S05...
  • Page 8 VEL-AV0M03-NKTX VELOCITY 3 A/V+ DVI VIDEO EXTENDER, SINGLE LINK DVI, LOCAL DVI PORT, DDC, SERIAL, AUDIO, MULTI MODE, TX, NEUTRIK VOP-M04 VELOCITY 3 AV+ optics option for TX or RX, MULTI MODE, DUAL FIBER, 50M, or 350M or 1000M, LC or NEUTIK LC VOP-M01 VELOCITY 3 AV+ optics option for TX or RX, MULTI MODE, DUAL FIBER, 50M or 350M or 1000M, SC or ST...
  • Page 9 VEL-000M63-LCTX 3-in-1 VELOCITY 6, DVI VIDEO EXTENDER, LOCAL DUAL DVI PORT, DDC, MULTI- MODE, TX, LC VEL-000M63-SCRX 3-in-1 VELOCITY 6 DVI VIDEO EXTENDER, DUAL LINK DVI AUX DUAL DVI OUTPUT, DDC, MULTI-MODE, RX, SC VEL-000M63-SCTX 3-in-1 VELOCITY 6, DVI VIDEO EXTENDER, LOCAL DUAL DVI PORT, DDC, MULTI- MODE, TX, SC VEL-000M63-STRX 3-in-1 VELOCITY 6 DVI VIDEO EXTENDER, DUAL LINK DVI AUX DUAL DVI...
  • Page 10 VEL-AN0M06-LCRX VELOCITY 6 A/N+ DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DVI OUTPUT, DDC, SERIAL, AUDIO, MULTI-MODE, RX, LC VEL-AN0M06-LCTX VELOCITY 6 A/N+ DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DVI PORT, DDC, SERIAL, AUDIO, MULTI-MODE, TX, LC VEL-AN0M06-SCRX VELOCITY 6 A/N+ DVI VIDEO EXTENDER, DUAL LINK DVI, AUX DVI OUTPUT, DDC, SERIAL, AUDIO, MULTI-MODE, RX, SC VEL-AN0M06-SCTX VELOCITY 6 A/N+ DVI VIDEO EXTENDER, DUAL LINK DVI, LOCAL DVI PORT, DDC,...
  • Page 11: Laser Information

    The DVI Extender models Velocity-3, -6, -33 and -63 are designed and identified as Class 1 LASER products. 2. System Features 2.1. General System Features Thinklogical’s VelocityDVI Extender Systems are designed for high resolution video extension ® applications, such as remote projection centers, theaters and assembly halls, and for secure computer installations.
  • Page 12: Basic Operation

    LED information to the RX. The RX cannot send any information to the TX. In this mode the RX buttons are inoperative. Also, DDC information can only be gathered from the TX local port or the Thinklogical default EDID table. 2.4 Dual Fiber Operation, System-3 In this mode video information is transmitted from the TX to the RX over fiber L1.
  • Page 13: Technical Specifications (Systems-3, -6, -33 And -63)

    2. 6 Technical Specifications (Systems-3, -6, -33 and -63) Technical Specifications (Systems-3, -6, -33, -63) Vel-3: Any single-link DVI resolution Video Resolution Vel-6: Any single-link or dual-link DVI resolution Transmitter Video DVI-D (2) Power 2.5 mm power connector Fiber Connections ST, SC, LC or Neutrik ®...
  • Page 14: Velocity Unbalanced Audio Specifications

    2.7 Velocity Unbalanced Audio Specifications 3. Installing DVI Extenders All physical connections to these products use industry-standard connectors. It is recommended that you securely mount each VelocityDVI chassis before installing the cabling and power sources. Please refer to the following appendices at the back of this manual: Appendix A: Installation Overview on pages 39-44 Appendix B: DVI Extender Mounting on page 45 Appendix C: RJ-45 Adapter Pin-outs on page 46...
  • Page 15: Ac Power

    3 . 1 AC Power Two wall pack AC/DC adapters (PWR-000022-R) are included with the VelocityDVI-3 and VelocityDVI-6 models. The AC wall pack has a universal power rating of 100-240VAC, 50-60Hz and also has interchangeable wall plug adapters for various international AC power receptacles (below).
  • Page 16: The Velocity Dvi-3, -6, -33, -63 Chassis Configurations

    3.2 The VelocityDVI-3, -6, -33 and -63 Chassis Configurations The models depicted on pages 14-30 provide an overview of the various dimensions, connectors and features available on Thinklogical’s VelocityDVI-3 and -6 chassis. The VelocityDVI-33 and -63 back panels are shown on page 30.
  • Page 17 VelocityDVI-3 with Neutrik ® OpticalCon DUO Connector TRANSMITTER DDC MODE ACQUIRE STATUS LCL REM POWER SELECT 5 VDC L1 L2 DVI to Local Display DVI from CPU RECEIVER DDC MODE ACQUIRE STATUS LCL REM POWER SELECT 5 VDC L2 L1...
  • Page 18 VelocityDVI-3 A/V+ 1.10" (27.94mm) TRANSMITTER DVI to Local Display DVI from CPU DDC MODE ACQUIRE LINE STATUS LCL REM SERIAL POWER SELECT 5 VDC 1.10" (27.94mm) RECEIVER DVI to Display DVI to Display DDC DDC MODE LINE ACQUIRE STATUS LCL REM...
  • Page 19 VelocityDVI-3 A/V+ with Neutrik® OpticalCon DUO Connector TRANSMITTER POWER 5 VDC DDC MODE ACQUIRE STATUS LINE LCL REM SERIAL SELECT L1 L2 DVI to Local Display DVI from CPU RECEIVER POWER 5 VDC DDC MODE ACQUIRE STATUS LINE LCL REM...
  • Page 20 VelocityDVI-3 A/N+ Transmitter (Audio Network) LNK/ACT Power 5VDC Velocity Digital Video Extension System – 3A/N+ Transmitter Status Powered by MRTS Technology ◄ Video/Data ► Data 7.00" (177.80mm) L x 7.49" (190.25mm) W x 1.10" (27.94mm) H Rear Panel Network Status LEDS: Front Panel Network Status LEDS: FOL is ON when Fiber Optic Link is OK.
  • Page 21 VelocityDVI-3 A/N+ Receiver (Audio Network) LNK/ACT Power 5VDC Velocity Digital Video Extension System – 3A/N+ Receiver Status Powered by MRTS Technology ◄ Data ► Video/Data 7.00" (177.80mm) L x 7.49" (190.25mm) W x 1.10" (27.94mm) H Front Panel Network Status LEDS: Rear Panel Network Status LEDS: FOL is ON when Fiber Optic Link is OK.
  • Page 22 VelocityDVI-3 A/N+ Transmitter with Neutrik® OpticalCon DUO Connector LNK/ACT Power 5VDC Velocitydvi Digital Video Extension System – 3A/N+ with Neutrik Connector ® Transmitter Status Powered by MRTS Technology ◄ Video/Data Neutrik Connector ® ► Data 7.00" (177.80mm) L x 7.49" (190.25mm) W x 2.00" (50.80mm) H...
  • Page 23 Front Panel Network Status LEDS: Rear Panel Network Status LEDS: FOL is ON when Fiber Optic Link is OK. 10/100: TX is ON when data is transferring from TX to RX. When lit, speed of link is 100 Mb/sec. RX is ON when data is transferring from RX to TX. When off, speed of link is 10 Mb/sec.
  • Page 24 VelocityDVI-6 DVI to Local TRANSMITTER Display DVI from CPU DDC MODE ACQUIRE STATUS LCL REM POWER SELECT 5 VDC RECEIVER DVI to Display DDC DVI to Display RECEIVER DDC MODE ACQUIRE STATUS LCL REM POWER SELECT 5 VDC Velocity Digital Video Extension System – 6 Dual-Link DVI Transmitter Lower Connectors...
  • Page 25 VelocityDVI-6 with Neutrik® OpticalCon QUAD Connector TRANSMITTER DDC MODE ACQUIRE STATUS LCL REM POWER SELECT 5 VDC DVI to Local Display DVI from CPU RECEIVER DDC MODE ACQUIRE STATUS LCL REM POWER SELECT 5 VDC DVI to Display DDC DVI to Display Video ►...
  • Page 26 VelocityDVI-6 A/V+ 1.10" (27.94mm) TRANSMITTER DVI to Local Display DVI from CPU DDC MODE ACQUIRE LINE STATUS LCL REM SERIAL POWER SELECT 5 VDC 1.10" (27.94mm) RECEIVER DVI to Display DVI to Display DDC DDC MODE LINE ACQUIRE STATUS LCL REM SERIAL POWER SELECT...
  • Page 27 VelocityDVI-6 A/V+ with Neutrik® OpticalCon QUAD Connector TRANSMITTER POWER 5 VDC DDC MODE ACQUIRE STATUS LINE LCL REM SERIAL SELECT DVI to Local Display DVI from CPU RECEIVER POWER 5 VDC DDC MODE ACQUIRE STATUS LINE LCL REM SERIAL SELECT DVI to Display DDC DVI to Display Velocity...
  • Page 28 VelocityDVI-6 A/N+ Transmitter LNK/ACT Power 5VDC Velocity Digital Video Extension System – 6A/N+ Status Dual-Link DVI Transmitter Powered by MRTS Technology Lower Connector Lower Connector ◄ ► Video/Data Data ◄ Video 7.00" (177.80mm) L x 7.49" (190.25mm) W x 1.10" (27.94mm) H Front Panel Network Status LEDS: Rear Panel Network Status LEDS: FOL is ON when Fiber Optic Link is OK.
  • Page 29 VelocityDVI-6 A/N+ Receiver LNK/ACT Power 5VDC Velocity Digital Video Extension System – 6A/N+ Dual-Link DVI Receiver Status Powered by MRTS Technology Lower Connector Upper Connector ► ◄ Video Data ► Video/Data 7.00" (177.80mm) L x 7.49" (190.25mm) W x 1.10" (27.94mm) H Front Panel Network Status LEDS: Rear Panel Network Status LEDS: FOL is ON when Fiber Optic Link is OK.
  • Page 30 Front Panel Network Status LEDS: Rear Panel Network Status LEDS: FOL is ON when Fiber Optic Link is OK. 10/100: TX is ON when data is transferring from TX to RX. When lit, speed of link is 100 Mb/sec. RX is ON when data is transferring from RX to TX. When off, speed of link is 10 Mb/sec.
  • Page 31 Velocity-6 A/N+ Receiver with Neutrik® QUAD OpticalCon Connector LNK/ACT Power 5VDC Velocity Digital Video Extension System – 6A/N+ with Neutrik Connector ® Dual-Link DVI Receiver Status Powered by MRTS Technology ► Video Neutrik Connector ® ► ◄ Video/Data Data 7.75" (196.85mm) L x 7.49" (190.25mm) W x 2.00" (50.80mm) H Front Panel Network Status LEDS: Rear Panel Network Status LEDS: FOL is ON when Fiber Optic Link is OK.
  • Page 32: Table Of Velocitydvi Chassis Dimensions

    VEL-63 (rack-mount) 19.0"W x 7.84"D x 1.72"H 482.60mm x 199.14mm x 43.69mm Refer to Paragraph 1.3 beginning on page 5 for the complete line of VelocityDVI-3 & -6 Extenders. Page 30 2 0 1 3 V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,...
  • Page 33: Ddc (Display Data Channel ) And Edid (Extended Display Identification Data )

    4. DDC and EDID (Display Data Channel) is a VESA standard transport medium between a CPU’s graphics adapter and monitor. The DDC is used to pass EDID (Extended Display Identification Data), which is stored in the monitor and describes its characteristics (vendor name, serial number, frequency range, etc.). With this information the CPU and video card can determine what resolutions the monitor is capable of.
  • Page 34: Load Default Edid Table

    Local Static mode operates in the same manner as Remote Static mode except that the EDID table is read from a monitor plugged into the local port of the TX. Once the ACQUIRE button is pressed the TX will begin reading the DDC from the locally connected monitor until a valid EDID table is read. The table will then be stored on the TX and presented to the CPU.
  • Page 35: Ddc Leds And Mode Button Operation

    4.2.1 DDC LEDs and Mode Button Operation • Acquire Button The upper button is the Acquire Button. This button is used to initiate DDC collection. This button works with all modes except Pass-Thru. • Select Button The lower button is used to select the DDC Mode of operation. The modes will cycle through Remote Dynamic, Remote Static, PassThru and Local Static.
  • Page 36: Regulatory And Safety Compliance

    5.2. Regulatory Compliance Thinklogical VelocityDVI Extender products are designed and made in the USA. VelocityDVI Extender products have been tested by a nationally recognized testing laboratory and found to be compliant with the following standards (both domestic USA and many international locations).
  • Page 37: Australia & New Zealand

    5.2.2. Australia & New Zealand This is a Class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take corrective measures. 5.2.3. European Union 5.2.3.1. Declaration of Conformity Product name VelocityDVI Digital Video Extension System-3, VelocityDVI Digital Video Extension System-6, VelocityDVI Digital Video Extension System-33, VelocityDVI Digital Video Extension System-63...
  • Page 38: Product Serial Number

    Please use one of the following email addresses: info@thinklogical.com – Information on Thinklogical and our products. ® sales@thinklogical.com – Sales Department - orders, questions or issues. support@thinklogical.com – Product support, technical issues or questions, product repairs and request for Return Authorization. Page 36 2 0 1 3 V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v .
  • Page 39: Telephone

    If you wish to return your device, contact the Thinklogical authorized dealer where you purchased the ® device, or if you purchased directly, call Thinklogical at 1-800-291-3211 (USA). Page 37 2 0 1 3 V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,...
  • Page 40: Return Merchandise Authorization

    Return Authorization If you have any issue with any Thinklogical product, have product questions or need technical assistance with your Thinklogical system, please contact Customer Support at 1-800-291-3211 (USA only) or 1- 203-647-8700 and let us help. If you must return a product to Thinklogical directly, Customer Support will ask you to describe the ®...
  • Page 41: Appendix A: Installation Overview

    Appendix A: Installation Overview A.1. VEL-3 Velocitydvi Digital Video Extender-3 Installation Overview STEP 4: Connect the supplied AC Power Adapter (PWR-000022-R) to the Tx and Power Supply plug it into a standard AC source. (PWR-000022-R) Local Monitor STEP 5: Connect the video source (CPU) to the Tx with a DVI-D M-M Transmitter VEL-000M03-LCTX Cable.
  • Page 42: Vel-3 A/V

    A.2. VEL- 3 A/V+ Page 40 2 0 1 3 V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,...
  • Page 43: Vel-6

    A.3. VEL-6 Velocitydvi Digital Video Extender-6 Dual-Link Installation Overview STEP 4: Connect the supplied AC Power Adapter (PWR-000022-R) to the Tx and Power Supply plug it into a standard AC source. (PWR-000022-R) Local Monitor STEP 5: Connect the video source Transmitter VEL-000M06-LCTX (CPU) to the Tx with a DVI-D M-M Cable.
  • Page 44: Vel-6 A/V

    A.4. VEL-6 A/V+ Velocitydvi Digital Video Extender-6AV+ Installation Overview STEP 4: Connect the supplied AC Power Adapter (PWR-000022-R) to the Tx and Power Supply plug it into a standard AC source. (PWR-000022-R) RJ45 to Local Monitor Transmitter VEL-AV0M06-LCTX STEP 5: Connect the video source (CPU) to the Tx with a DVI-D M-M Cable.
  • Page 45: Vel-33

    Copyright 2013. All rights reserved. Printed in the U.S.A. All trademarks and service marks are the property of their respective owners. STEP 6: Using the supplied DVI-D male to male cables, connect the video output sources to the Transmitter Unit’s DVI IN receptacles.
  • Page 46: Vel-63

    A.6 VEL-63 Page 44 2 0 1 3 V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,...
  • Page 47: Appendix B: Dvi Extender Mounting

    Appendix B: DVI Extender Mounting Each VelocityDVI Extender-3 and -6 can be used as a desk top or wall-mounted device. Mounting centers are provided with keyhole slots. Users may choose the most appropriate fasteners and anchors to mount each unit according to the requirements of each application. VelocityDVI-33 and -63 chassis can be desk-top (feet provided) or standard EIA 19”...
  • Page 48: Appendix C: Rj45 Adapter Pin - Outs

    Appendix C: RJ-45 Adapter Pin-outs Page 46 2 0 1 3 V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l , R e v . G , M a y ,...
  • Page 49: Appendix D: Automatic Fail-Over Option

    Appendix D: Automatic Fail-Over Option For applications in need of an Automatic Fail-Over system, Thinklogical offers a solution to meet this need. This option allows for two separate fiber paths and the ability to select which of the two paths is the viable path. This feature is available on the transmitter unit only.

This manual is also suitable for:

Velocitydvi-33Velocitydvi-6Velocitydvi-63

Table of Contents