Logic Sub-Menu - BFT ECOSOL Installation Manual

Libra ul-r pre-wired enclosure
Hide thumbs Also See for ECOSOL:
Table of Contents

Advertisement

WHILE IN THE SUB-MENU
Navigation of the sub-menu is the same as the main menu. Once a sub-menu selection has been made:
USE
TO TURN ON AND
USE THE
BUTTON AS "ENTER" TO CONFIRM THE DESIRED VALUE
PRESS
AND
LOGIC OPTIONS
DISPLAY

LOGIC SUB-MENU

TO TURN OFF THE SELECTED FEATURE.
AT THE SAME TIME TO RETURN TO THE MAIN MENU
TCA – Auto Close Timer. Default: OFF
3 STEP – Instant reverse. Gate instantly reverses on START activation during the
CLOSE cycle as opposed to stopping and requiring a 2
Default: OFF
IBL OPEN – Ignore START input during OPEN cycle . Default: OFF
FAST CLS – Gate closes immediately after SAFETY input is cleared. Default: OFF
PHOTOC OPEN – Ignore SAFETY input during OPEN cycle. If OFF, gate stops on
SAFETY input activation during the OPEN cycle. Default: OFF
TEST PHOT – Enables the SAFETY input supervision circuit. Default: OFF
1 MOT ON – Single gate operation. Ignores MOTOR 1. Default: OFF
BLOC PERSIST – Operator pushes for 0.5 seconds after CLOSE limit is
reached. PHYSICAL GATE STOP IS REQUIRED. Default: OFF
START-CLOSE – Converts START/CLOSE input into CLOSE ONLY input.
Default: OFF
FIXED CODE – Disables the receiver's rolling code feature. Default: OFF
RADIO PROG – Enables Quick Remote Programming. Default: ON
MASTER – NOT USED. Default: OFF
www.BFTGateOpeners.com | (800) 878-7829
DESCRIPTION
nd
START input for re-opening.
DO NOT USE WITH ECOSOL
NO EFFECT WITH ECOSOL
NO EFFECT WITH ECOSOL