NATURAL TO LP GAS CONVERSION

This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's instructions
and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions
is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, per-
sonal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The in-
stallation is not proper and complete until the operation of the converted appliance is checked as specified in the
owner instructions supplied with the kit.
Cet équipement de conversion sera installé par une agence qualifiée de service conformément aux instructions du
fabricant et toutes exigences et codes applicables de l'autorisés avoir la juridiction. Si l'information dans cette In-
struction n'est pas suivie exactement, un feu, explosion ou production de protoxyde de carbone peut résulter le
dommages causer de propriété, perte ou blessure personnelle de vie. L'agence qualifiée de service est esponsable
de l'installation propre de cet équipement. L'installation n'est pas propre et complète jusqu'à l'opération de l'appareil
converti est chèque suivant les critères établis dans les instructions de propriétaire provisionnées avec l'équipement.
Kit # HA-92-00014 for Mendota Model FV-41 ARCH
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's instructions and
all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not
followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury
or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not
proper and complete until the operation of the converted appliance is checked as specified in the owner instructions sup-
plied with the kit.
Caution: The electrical supply to the fireplace must be turned off prior to performing the conversion. The gas supply
must be shut off prior to disconnecting the electrical power.
ORIFICE SIZES REQUIREMENT:
A Natural Gas to LPG conversion kit #HA-92-00014 must be ordered and installed to convert the FV-41 ARCH Fireplace
to burn LPG.
LP Conversion Kit #HA-92-00014 contains the following parts: One Motorized LP Pressure Regulator, Two Cap Orifices
drill #54, and Conversion Decal.