FULLVIEW RECTANGLE DIRECT VENT GAS FIREPLACE HEATER
WARNING: If the information in this manual is not followed
exactly, a fire or explosion may result causing property dam-
age, personal injury or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
·
Open windows.
·
Do not touch electrical switches.
·
Do not try to light any appliance.
·
Extinguish any open flame.
·
Do not use the phone in your building.
·
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
·
If you cannot reach your gas supplier, call the fire
department.
·
Installation and service must be performed by a
qualified installer, service agency or the gas suppli-
er.
WARNING
Do NOT use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control, which has been under water.
Model FV-41-M-PF2 (MODERN)
OWNER'S MANUAL
DOCUMENT NO. FV41-MODERN-PF2-OM-1012
AVERTISSEMENT : Assurez-vous de bien
les instructions donné dans cette notice pour réduire au min-
imum le risque d'incendie ou pour éviter tout dommage
matéeriel, toute blessure ou la mort.
·
Ne pas entreposer ni utiliser d'essence ni d'autres vape-
rurs ou liquides inflammables dans le voisinage de cet
appareil ou de tout autre appareil.
·
QUE FAIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
·
Ne pas tenter d'allumer d'appareil.
·
Ne touchez à aucun interrupteur. Ne pas vous servir des
téléphones se trouvant dans le batiment où vous vous
trouvez.
·
Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
·
Si vous ne pouvez rejoindre le fournisseur de gaz, appe-
lez le service dos incendies.
·
L'installation et service doit être exécuté par un quali-
fié installer, agence de service ou le fournisseur de gaz.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR : Laissez cette notice avec l'appareil.
CONSOMMATEUR : Conservez cette notice pour consulta-
tion ultérieure.
suivre

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FV-41-M-PF2 MODERN and is the answer not in the manual?

Questions and answers

Summary of Contents for Mendota FV-41-M-PF2 MODERN

  • Page 1 FULLVIEW RECTANGLE DIRECT VENT GAS FIREPLACE HEATER Model FV-41-M-PF2 (MODERN) OWNER’S MANUAL DOCUMENT NO. FV41-MODERN-PF2-OM-1012 WARNING: If the information in this manual is not followed AVERTISSEMENT : Assurez-vous de bien suivre exactly, a fire or explosion may result causing property dam- les instructions donné...
  • Page 2: Table Of Contents

    FV-41 DOOR REMOVAL AND INSTALLATION ........................12 TO REMOVE DOOR ................................12 TO REPLACE DOOR ................................12 FV-41-M BURNER MEDIA INSTALLATION INSTRUCTIONS ..................... 13 FLAME APPEARANCE ADJUSTMENT ..........................13 MENDOTA EXTENDED PROTECTION AND LIMITED WARRANTY ................. 14 NOTES ....................................14 2 | P a g e...
  • Page 3: Safety And Warning Information

    WARNING Cet appareil peut être installé dans un maison Mendota gas fireplaces are heat producing applianc- préfabriquée (mobile) déjà installée à demeure si les es. Do not burn wood, paper or other materials in this règlements locaux le permettent.
  • Page 4 Clothing or flammable material SHOULD NOT BE PLACED on or near the appliance. On ne devrait pas placer de vêtements ni d’autres matières inflammables sur l’appareil ni à proximité. Children and adults should be ALERTED to the hazards of high surface temperature and should STAY AWAY to avoid burns or clothing ignition.
  • Page 5: Specifications

    HIGH ALTITUDE INSTALLATION INFORMATION: Prior to installing at altitudes higher than 7500 feet, please contact the Mendota technical service department for specific venting requirements and venting restrictions. 5 | P a g e...
  • Page 6: Congratulations

    Fireplace and replace any part of the control system and any gas control, which has been under water. DO NOT use this fireplace if the burner does not light immediately. Turn unit off and call Mendota ap- proved service person if there is any delay in burner light off.
  • Page 7: Before You Begin

    BEFORE YOU BEGIN Read this entire manual before you use your new fireplace (especially the section “Safety Precautions” on page 2). Failure to follow the instructions may result in property damage, bodily injury, or even death. Remote Control Transmitter Functions NOTE: The Wall Receiver will “beep”...
  • Page 8: Remote Transmitter Operating Instructions

    In SMART mode, the flame height regulates automatically. Accent-Light Dimmer: This function controls the Mendota Accent Light functions. Pressing the UP key in this mode will TURN ON the Accent Light and allow you to control the brightness of the Accent Light in 6 steps.
  • Page 9: Temperature Indicator ( F Or C)

    TEMPERATURE INDICATOR ( F or 1. Press the ON/OFF Key and Turn Off the Fireplace. 2. Simultaneously, Press both the MODE Key and the Thermostat Key. 3. Look at the LCD display to verify that your desired indicator ( F or C) is being displayed.
  • Page 10: First Time" Pilot Lighting Instructions

    “FIRST TIME” PILOT LIGHTING INSTRUCTIONS IMPORTANT: Be sure all items on "INSTALLATION CHECK OFF LIST" in the Installation Manual have been completed! CAUTION: If the pilot goes out, be sure to wait a minimum of five minutes before attempting to relight the pilot. 1.
  • Page 11: Ipi/Standing Pilot System Information

    DOWN arrow button to set “IPI” mode. Once set to the desired setting, press On/Off button to activate the fireplace. NOTE: Mendota Fireplaces recommends that the (CPI) Standing Pilot Mode be used during the winter months when the average daily high temperature falls below 50 F.
  • Page 12: Fv-41 Door Removal And Installation

    FV-41 DOOR REMOVAL AND INSTALLATION TO REMOVE DOOR 1. Use the glass latch tool to disconnect the spring latches from the glass frame. Insert tool into hole in latch, pull towards you and Rotate 90 degrees to disengage top latches. Remove tool. There are two spring latches on top of this gas fireplace.
  • Page 13: Fv-41-M Burner Media Installation Instructions

    à ces schémas et ou si des pièces autres que celles spécifiquement approuvées avec cet appareil sont utilisées. Two media choices are available directly from Mendota for use on the FV41-M model. Select one media and purchase separately.
  • Page 14: Mendota Extended Protection And Limited Warranty

    This warranty is non-transferable and is made to the original retail purchaser, provided the purchase was made through an authorized Mendota deal- Mendota is not responsible for any damage to or malfunction of the Fireplace unless caused by a defect in material or workmanship from normal home use.
  • Page 15 15 | P a g e...
  • Page 16 Johnson Gas Appliance Company 520 E Avenue N.W. - Cedar Rapids, IA 52405 Mendota Hearth Division WEBPAGE: www.johnsongas.com or www.mendotahearth.com 85-03-00890 16 | P a g e...

Table of Contents