NATURAL TO LP GAS CONVERSION

This conversion must be made by a qualified service technician.
1.
Install main burner orifice #65-14-00050 (#50 drill) see pg. 42 for location.
Orifice is removed and installed with a ½" deep well socket and ratchet.
2.
Install pilot orifice #05-04-00036 (.014") see pg. 45 for location. Remove and install pilot
hood with 7/16" open-end wrench. (Pilot orifice thimble is located inside pilot hood base.
3.
Install the new LP Pressure Regular onto the gas valve body in the same position and orienta-
tion as the NG Pressure Regulator you removed in Step 2, above. The LP Pressure Regulator
can only be mounted in one position. Secure the LP Pressure Regulator in place using the 3
screws you removed in Step 2. Tighten down using a ¼" flat blade screwdriver.
HA-30-00237 (OPTIONAL)
LP PRESSURE
REGULATOR
SCREWS
NG PRESSURE
REGULATOR
35
GAS VALVE BODY