1. Make 12V (+) and (–) and data in and data out connections from the Phone
Color Lead
2. Insert the keyed connector at the other end of the connector cable into the
3. Connect terminals 1 through 5 on the Phone module as shown in the Wiring
Use an RJ31X jack with a direct-connect cord and make all connections
exactly as shown. If the leads on the direct-connect cord are too short to
reach their assigned terminals, splice additional wires to them, as required.
4285 Terminal
1: Phone In (Tip)
2: Phone In (Ring)
3: Phone Out (Tip)
4: Phone Out (Ring)
5: Ground
6: Not Used
7: Not Used
If no touch tones are produced following access to the security system from
on-premises (this problem may arise in rare cases), it may be necessary to
reverse the wires connected to terminals 3 and 4 on the Phone module and
the wires connected to terminals (17) & (18) on the control. The wiring
diagram shows the wiring connections that will provide proper operation in
most cases.

Caller ID Units

If the telephone system on the premises includes a Caller ID unit, connect the
ID unit directly to the "Handset" terminals (17 &18) on the control, as shown in
4285 Phone module Wiring Connections diagram that follows.
module to the control, using the connector cable supplied with the Phone
module (see Figure 12).
Terminal On Control *
GREEN
DATA IN (terminal 6)
BLACK
AUX – (terminal 4)
RED
AUX + (terminal 5)
YELLOW
DATA OUT (terminal 7)
mating header on the Phone module (see diagram on next page for location
of the header).
Table and in the 4285 wiring diagram that follows.
4285 WIRING TABLE
8 –2
*
These are the same connections
as those used for remote
keypads
Connects to:
Terminal (17) on control.
Terminal (18) on control.
BROWN lead from direct-connect cord.
GRAY lead from direct-connect cord.
Earth ground terminal (21) on control.
.