Press 73 AC RESTORE REPORT CODE
This is sent when AC power has been restored after an AC power
outage.
Press 74 LOW BAT RESTORE REPORT CODE
This is sent when a system low battery condition is restored to
normal.
Press 75 RF XMTR. LOW BATTERY RESTORE CODE
This is sent when a transmitter that previously sent in a low battery
message has sent a message indicating it no longer has a low
battery condition.
Press 92 NUMBER OF REPORTS IN ARMED PERIOD
This option can be used to limit the number of messages (alarm &
alarm restore reports) sent to the central station in an armed
period. "0" limits reports to a total of 10; "1" allows an unlimited
number of reports.
Press 94 DOWNLOAD PHONE NUMBER
Enter up to 12 digits;
0–9, # + 11 for " ", # + 12 for "#", # + 13 for a pause. Do not fill
unused spaces. End field by entering " ". To clear entries, press
94 .
Press 95 RING DETECTION COUNT FOR DOWNLOADING
Refer to the chart below and program this field accordingly.
Voice
Answering
Module
Machine
Yes
No
Yes
Yes
Yes
No
Yes
Yes
No
No
No
Yes
No
No
No
Yes
Important Note: If "15" is entered in field
4285 Phone Module is included in the installation, you should note the following:
When calling in from an off-premises phone (to receive a status report or execute a
command), the user should make the initial call, allow 1 to 3 rings only, and hang up.
Then call in again – the Phone Module will now seize the line, and 2 long tones will
heard, followed by the usual voice prompt for the 2-digit phone access code. If this
procedure is not followed, Phone Module operation will not be possible.
96
INITIALIZE DOWNLOAD ID AND SUBSCRIBER ACCT. No. FOR
DOWNLOADING (No data entry required)
This completes the communication programming.
Exit the programming mode by keying 99.
Refer to the TESTING THE SYSTEM section to check system operation.
15–7
Downloading
Field 95 Programming
No
Set for value other than "0" (1–14). This
will enable the control panel to answer
the phone call. Otherwise, it will not be
possible to access the module.
No
Set for a value higher than the number of
rings for which the answering machine is
set. Example: if machine is set for 4
rings, use value 5 or higher. This is
recommended so that the Phone module
can still be accessed if the answering
machine is turned off and does not
answer the phone call.
Yes
Set for value other than "0" (1–14).
Yes
"15" to bypass answering machine.
No
Enter "0"
No
Enter "0"
Yes
Enter 1–14
Yes
Enter 15. See Imortant Note below.
95 to bypass an answering machine, and a