12

Control panel programming sequences

Function
Entering enrollment mode
One wireless device (detector, keypad, key
fob, siren or sub control panel) can be
enrolled to each address from 01 to 50.
The system offers vacant addresses one
by one, if all addresses are occupied no
devices can be enrolled.
A device enrolled to address 01 to 30
disables the corresponding hard-wired
input 01 to 30.
In addition to enrollment mode, devices can
also be enrolled by keying in their production
codes (see 6.42).
Exit delay time
Entrance delay time
Alarm duration time
PGX function
PGY function
Enablement of telephone number changes
in maintenance mode
Radio interference indication
Radio communication supervision
RESET enabled
Master control panel enrollment to a sub
control panel for setting (arming) control
Master code reset
Measuring signal strength
Enrolling the control panel to UC, AC or a
sub control panel
Setting (arming) without an access code
Triggered detector indication
by text on the keypad display
Confirmation of intruder alarms
In this mode, the triggering of an intruder
detector in a set (armed) section will only be
recorded to the memory as an unconfirmed
alarm and if then followed by the activation
of any other intruder detector within 40
minutes, an alarm will be triggered. If the first
triggered detector has a DEL reaction and it
is not confirmed by any other detector, it will
not trigger an alarm after the entrance delay
has expired.
JA-82K control panel installation manual
Options
Sequence
Keys:
1
= address scrolling
and
holding 2= erases the
displayed address
holding 4 = erases all
addresses
# = exiting enrollment mode
20x
x = 1 to 9 (x10 s =10 to 90 s)
21x
x = 1 to 9 (x 5 s = 5 to 45 s)
22x
x = 1 to 8 (min.), 9=15min
x in an unsplit system:
0 - whole system set (ABC) =
PG on
1 - any system part set = PG
on
2 - AB set (not C) = PG on
3 - Fire alarm = PG on
4 - Panic alarm = PG on
23x
5 - Any alarm = PG on
24x
(excluding Panic)
6 - AC dropout = PG on
7 - PG on/off (by ∗80 /∗81 for
PGX and ∗90/∗91 for
PGY)
8 – Single 2 s pulse (keys
∗8=X, ∗9=Y)
25x
251 = YES
250 = NO
26x
261 = YES
260 = NO
271 = YES
270 = NO
27x
28x
281 = YES
280 = NO
290
The sequence triggers
enrollment.
Returns master code to 1234 It has no effect on other
291
298
Activates measurement
299
The sequence triggers
enrollment.
30x
301 = YES
300 = NO
31x
311 = YES
310 = NO
321 = YES
320 = NO
32x
fig. 18 Summary of the programming sequences
- 17 -
Setting to
Factory
comply with
default
EN-50131-1
nothing
connecting their power
(battery) except keyfobs which
enroll by pressing & holding a
pair of their buttons
is indicated by the A indicator
being lit
a new address will move it
there
30s
if a final door detector is used,
then x is multiplied by 30s
20s
instead (i.e. from 30 to 270s)
4 min.
0=10s (for testing)
x in a split system
7
0 - alarm A = PG on
on/off
1 - alarm B = PG on
2 - entrance delay A = = PG on
(∗80/∗81)
3 - entrance delay B = PG on
1
4 - A set = X on, B set = Y on
5 - A panic = X on, B panic = Y
any
on
system
6 - Fire = X on, AC dropout = Y
part set
on.
7 - PG on/off (by ∗80 /∗81for
PGX and ∗90/∗91 for PGY)
8 – Single 2 s pulse (keys
∗8=X, ∗9=Y)
NO
see communicator
NO
YES
30s or longer
NO
YES
YES
(Un)setting the master
control panel will (un)set
the sub control p.
The sub c. panel must be
in enrollment mode.
codes and it is recorded in
the control panel memory
arrow keys scroll
addresses,
# halts measurement.
see 6.9
YES
NO
by keying: A, B, ABC, ∗1, ∗2,
∗3, ∗4
allows the display of open
YES
windows & doors,
to view details press ?
An alarm can be confirmed by
NO
any other intruder detector in any
section which is set (armed).
Notes
devices enroll by
an occupied address
enrolling a device to
MKH51102