sub control panel, it is also indicated on the master control panel. In this
configuration it is impossible to control the sub control panel from the master
control panel.
If it is desired to control a sub control panel from a master control panel (i.e.
setting/unsetting), it is possible to enroll a JA-8x OASiS master control panel
to a sub control panel as a remote control as follows:
1. First enroll the sub control panel to the desired address in the master
control panel by entering 299 on the sub control panel's keypad in
Service Mode – see 5.1 for full details.
2. Switch the master control panel to Service Mode.
3. In the sub control panel, enter enrollment mode by keying in "1" in Service
Mode and select the desired address.
4. In the master control panel enter 290. This way the control panel will
enroll to the sub control panel to the desired address as a remote control.
5. Switch both control panels to maintenance mode and check that all-
section setting of the master control panel also sets the sub control panel
and unsetting the master control panel unsets the sub control panel too.
Expect approximately 2 seconds of delay between control panels.
Notes for operating the sub control panel:
The sub control panel can still be operated independently via its keyfob or
keypad e.g. it can be set while the master control panel is unset. If the
master control panel changes its status later on, it will then control the sub
control panel to achieve synchronisation.
To disable the master control panel's ability to control the sub control
panel, enter the sub control panel's enrollment mode, select the address
where the master control panel is enrolled and erase the master control
panel from this address by pressing and holding key 2.
The status of the sub control panel is not displayed on the master control
panel.

6.10 Master code reset

If the master code has been forgotten or a card lost, it is possible to use the
following sequence to reset the master code to the factory-default 1234:
291
Note: Resetting the master code has no effect on other codes and cards.
Resets are recorded in the control panel memory and sent to the ARC.

6.11 Enrollment to other devices (UC, AC)

299
Keying in
sends an enrollment signal to enroll the control panel to UC-
82 or AC-82 receiving modules (see 5.5). This sequence can also be used to
enroll a sub control panel to a master control panel (see 6.9).

6.12 Setting (Arming) without an access code

"Hot" setting keys (short-cut keys for setting) A, B, ABC or entering "∗
number" can be enabled for use without a valid access code or card. If
disabled, then hot key use or entering "∗ number" has to be followed by a
valid access code or card to have any effect:
Function/sequence
All-section setting
Setting of A
Setting of AB (or B)
Event memory recall
fig. 10 setting / arming with or without code
If you remotely operate the system by mobile phone, you can press ∗1 for
the ABC key, ∗2 for key A, and ∗3 for key B.
Controlling the PG outputs by keying in ∗8 or ∗9 or pressing
unaffected by these settings. These keys can however be disabled by a
special sequence (see 6.26).
Factory default setting: Setting (arming) without an access code enabled.

6.13 Triggered-detector indication

Pressing the ? key checks if any detectors are permanently triggered, e.g. if
any doors or windows are open.
3 1 1
indication enabled
3 1 0
indication disabled
Factory default setting: indication enabled

6.14 Confirmation of intruder alarms

To reduce the risk of false alarms and to comply with British standard BSI
DD243, the control panel allows alarm confirmation logic to be enabled as
follows:
3 2 1
confirmation logic enabled
3 2 0
confirmation logic disabled
Confirmation logic:
JA-82K control panel installation manual
301
300
ABC key
Code/card
A key
A key, code/card
B key
B key, code/card
∗4
∗4 code/card
and
If the system is set (armed) and any intruder detector gets triggered, i.e. a
detector with an instant, delayed, or next-delayed reaction, an alarm will
not be caused but the control panel will record a so-called unconfirmed
alarm.
If any other intruder detector is triggered in a set section within 40 minutes
of the above event, an intruder alarm will be triggered. If no other detector
is triggered during this period, the control panel will stop waiting for
confirmation.
The alarm must be confirmed by another detector than the first one. If the
same type of detector is used for confirmation thentheir detection area
must not cover the same area.. This must be ensured by the proper
location of detectors.
An unconfirmed alarm is recorded in control panel memory but can also
be sent to the ARC, or to the user by SMS report.
If the first triggered detector has a delayed reaction, it will start a so-called
unconfirmed entrance delay. This delay is indicated the same way as an
ordinary entrance delay., If no other delayed detector is triggered during
this delay, there will be no alarm. If the entrance delay is exceededthe
unconfirmed alarm is recorded in the control panel memory. If there is any
other delayed or next-delayed detector triggered during the entrance
delay period, it will confirm the entrance delay, and if this delay is
exceeded (due to no unsetting being done) it will trigger an intruder alarm
at the end of the delay.
If a delayed detector is triggered within 40 minutes after the triggering of
an unconfirmed alarm or the moment the unconfirmed entrance delay is
exceeded, the confirmed entrance delay starts running and when it times
out (due to no unsetting being done), an intruder alarm is triggered.
If the unconfirmed entrance delay is confirmed by an instant detector it will
trigger an internal warning (IW) alarm immediately (e.g. an internal siren) and if
the entrance delay times out then an external alarm (EW) will be triggered.
An unconfirmed alarm can be confirmed by any other intruder detectors in
the system as long as the detectors are assigned to a set (armed) section.
The confirmation of intruder alarms concerns only detectors with instant,
delayed, or next-delayed reactions. It has no effect on fire, panic, 24-hour,
tamper, or technical alarms. These alarms are triggered immediately
without confirmation.
Note: When the first detector is triggered it begins a process which waits 40
minutes for any possible confirmation of the alarm (unconfirmed alarm status)
during which the system works exactly the same way as if the confirmation
function had not been enabled.
Warning: If intruder alarm confirmation is enabled, it is necessary to install
enough detectors in the building to detect an intruder even if he/she is only
moving in one particular place.
Factory default setting: confirmation disabled

6.15 Exit delay beeps

The exit delay can be indicated by beeps from the keypad and internal
wireless siren. The beeps get faster in the last 5 seconds.
3 3 1
Beeps enabled
3 3 0
Beeps disabled
Factory default setting: Beeps enabled.

6.16 Exit delay beeps while partially setting (arming)

The exit delay caused by partial setting, e.g. using the A or B key, can also
be indicated by keypad beeps and internal-siren beeps. The beeps get faster
in the last 5 seconds. The feature is linked to 331 parameter setting.
3 4 1
Beeps enabled
3 4 0
Beeps disabled
Factory default setting: Beeps disabled.
is

6.17 Entrance delay beeps

The entrance delay can be indicated by keypad beeps and internal-siren
beeps:
3 5 1
Beeps enabled
3 5 0
Beeps disabled
Factory default setting: Beeps enabled.

6.18 Setting (arming) confirmed by wired-siren chirp

A hard-wired siren connected to the IW terminal of the control panel can
audibly indicate setting by one beep, unsetting by two beeps and unsetting
after an alarm by three beeps. Four beeps mean an invalid attempt at setting
the system has occurred.
3 6 1
Chirps enabled
3 6 0
Chirps disabled
Note: In JA-80L wireless sirens, this function can be individually enabled for
each siren. (see the siren manual).
Factory default setting: Hard-wired siren chirps disabled
- 8 -