5

The JA-60 keypad(s)

The system can be programmed and operated by JA-60E
keypad(s). As a maximum, 4 keypads can be wired to the control
panel. The keypads can either be wired by cables equipped with
modular jacks or by standard cables to terminals 1234. The same
numbered terminals (pins in the connectors) must be linked
together. It is possible to combine arbitrary wiring with modular
connectors and ordinary cables - see diagram. Modular jack cable
should not be used for a distance longer than 10 meters.
When a control panel has a „R" radio module, it can also be
operated and programmed via a JA-60F wireless keypad(s).
The wireless system can also be operated by remote
controls RC-40, RC-22 & RC-60, as well as by a JA-60D
wireless keypad. The control panel can have up to 8 wireless
controllers.
It is also possible to operate and program the JA-63 system
via a connected PC with ComLink software (see section 12).
6

Installation of wireless items

If the control panel is equipped with a "R" radio module, it can
work with all types of JA-60 wireless items and wireless UC output
modules (see brief overview enclosed to this manual).
 Detectors – up to 32 wireless JA-60 detectors can be
enrolled to the control panel (two detectors can be
enrolled to each zone)
 Keypads and remote controls - up to 8 wireless
controllers can be enrolled to the control panel (JA-60F
and JA-60D keypads, RC-40, RC-22 and RC-60 remote
controls)
 JA-60A Wireless siren – one can be enrolled to A
position, if more sirens requested they can also be
enrolled to detectors positions
 Wireless output modules UC-216 and UC-222 have
relays, which copy the status of the control panel's
programmable outputs PgX and PgY. An unlimited
number of the UC modules can be used with each
system.
A JA-6x control panel can be enrolled as a
subsystem if more zones are required (Master & Slave
architecture).
The
information from the sub control panel and it can also
arm and disarm the subsystem panel if requested.
Follow the particular wireless item manual when
installing. After you install the item to the desired location,
leave it un-powered and without its cover. The method of
enrollment is described in section 9.1.
JA-63 „PROFI" Alarm System
master
control
panel
7

Back up battery installation

There is a space for a size 12V, 1.3 or 2.6Ah battery (battery
size should corresponding to a desired backup period). The
control panel recharges and checks the condition of the back up
battery. If the system is powered from the battery for an
extended time and the battery is nearly discharged, the control
panel will first trigger a technical alarm
disconnect the battery to prevent damage. After the main power
is on again, the battery will be re-connected and will be
recharged.
insert the battery into the control panel
connect the battery cables (red +, black - )
Warning - do not make any short connection of the battery
terminals!
8

First powering of the control panel

Check that all cables are connected correctly
Switch on the AC power – the self testing LED in the
control panel will start to flash
The JA-60E keypad will display a "P", confirming that
the system is in the programming mode (ready for
setting). If a wireless keypad JA-60F will be used in
the system, it should be enrolled at first - see part 9.1.
Note: if „P" is not displayed, the control panel is not in the factory
default setting. Perform a Factory default reset. (See section 11).
9

Control panel programming

Functions of the system can be customized. The most
convenient programming method is via a connected PC using
the Comlink software (see 12). Programming can also be
performed manually from the keypad:
If the control panel is not in the programming mode,
open it (entering F 0 SC - SC = Service Code, factory
default SC=6060) – The programming mode will be
indicated by a „P" on the LED display. This mode can
only be entered when the panel is disarmed. In this
mode, no alarm can be triggered. In the "P" mode,
detectors and other accessories can be enrolled, the
system parameters can be set up and the system can
be tested.
Any
terminated by pressing the N key.
To exit the programming mode, press the N key („P"
will turn off). If any fault is indicated when you try to exit
the programming mode see programming sequence
39x for more details.
receives
- 7 -
unfinished
programming
and
then it will
sequence
can
be
MGK55402

Advertisement

Table of Contents
loading

This manual is also suitable for:

Profi ja-63krProfi ja-63krg

Table of Contents