exiting Service Mode by entering 4hhmmDDMMYY, and then re-
adjust the clock to the correct time in maintenance mode. By tricking
the system this way, you can be notified on the desired date. (see
6.45, entering and exiting maintenance mode does not change the
notification date).
Example: If the date is 10 January 2007 and you wish to receive a
notification 6 months later on 10 July 2007, while still in Service Mode
change the system clock to 10 July 2007, i.e. the day and month of the
desired notification date. Then exit Service Mode and re-adjust the clock to
the correct time in maintenance mode.
Factory default setting: Annual inspection notification disabled.

6.33 Only single alarm indication

If this function is enabled, then only one intruder alarm may be indicated at
a time. Once an intruder alarm has been triggered and has not ended yet,
then no more alarms can be indicated no matter how many more times
triggering occurs. When the alarm ends, the system is then ready to indicate
the next single intruder alarm.
This is to limit the number of SMS reports sent if hard-wired PIR detectors
capable of being frequently triggered are installed in the system and the
system is not unset (disarmed) properly when someone enters the building.
6910
multiple simultaneous intruder alarms allowed
6911
single intruder alarm allowed only
Note:
A panic alarm can always be triggered with no limits (except when in
service and maintenance modes),
• Apart from this limitation the system also checks if any detector is
triggering multiple alarms during one arm period. If any detector has
caused at least three alarms in a row it is then automatically bypassed.
This bypass lasts until another detector triggers an alarm or until the next
arming of the system.

6.34 Setting (arming) by service code

Normally, it is not allowed to control the system via the service code. Using
this sequence, the installer can be authorized to set and unset the system by
means of a valid service code. This feature should only be enabled with the
explicit approval of the master code holder (system administrator):
6920
disabled
6921
enabled
Factory default setting: disabled

6.35 Audible panic alarm

If enabled, panic alarms can be indicated by internal and external warning
devices (sirens on IW and EW):
6930
silent panic alarm
6931
audible panic alarm
Note: If the sequence 370 is used, panic alarms are silent if any section
of the system is unset.
Factory default setting: silent panic alarm

6.36 Higher control-panel receiver-sensitivity

If enabled, this feature can extend the communication range between the
control panel and its wireless devices if there is no radio frequency
interference in the premises.
6940
standard control panel sensitivity
6941
higher control panel sensitivity
Note: The sensitivity of the control panel receiver should only be
increased if there is no RF interference as the radio range would only be
reduced if interference was present.
Factory default setting: standard control panel sensitivity

6.37 Access by code plus card

This feature increases security against unauthorised setting/unsetting
(arming/disarming):
6950
system access by code or card
6951
system only accessed by code and card if both are
assigned to the same user position
Notes:
• The system has up to 50 user positions (01 to 50) each capable of
having an access code and an access card assigned to it. If both a
code and a card are assigned to a user then the above sequences
(6950 and 6951) determine whether the user can use a code or a
card or whether he must present both a card and a code to gain
control over the system. If both, a card and a code have to be
presented, the order in which they are done is unimportant.
JA-82K control panel installation manual
• If only a card or only a code is assigned to a user, then the above
settings have no effect on users like this.
Factory default setting: system operated by code or card

6.38 Audible 24 hour intruder alarm

The 24-hour intruder alarm which can be triggered whether the system is
set or not, and can also be silent or audible (IW and EW) according to the
following sequences:
6960
silent 24-hour intruder alarm
6961
audible 24-hour intruder alarm
Note: If sequence 370 is programmed, the intruder alarm will be silent if
any section in the system is unset.
Factory default setting: audible 24 hour intruder alarm

6.39 Service mode only with service and user code

To prevent the installer from accessing Service Mode without a user's
permission, this feature (if enabled) makes it compulsory for the any user
code (or master code) to be entered directly after entering the service code to
access Service mode. Service Mode can then be entered by keying in ∗0
service-code user-code (or master-code).
6970
Only service code needed.
6971
Service code and user-code (or master-code) needed.
Factory default setting: Only service code needed.

6.40 Device reactions and section assignment

The following sequence programs the characteristics of system devices:
61 nn r s
where
nn
is the device address from 01 to 50 (01 to 04 ... 14 can
either be the hard-wired input terminals in the control panel or
enrolled wireless devices)
r
is the reaction index from 0 to 9 – see Chyba! Nenalezen
zdroj odkazů.
s
is the section 1 = A, 2 = B, 3 = C (only has an effect if
partial setting or system splitting is used – except for PG
output control – See 6.23)
R
Reaction
0
Disabled
For temporarily disabling codes or devices
(none)
including tamper sensors
1
Natural
For detectors = instant, delayed or fire (selectable
in detectors by DIP switch)
For hard-wired inputs of the control panel or
keypad = delayed
Keyfobs
buttons = panic
Code = set/unset (see reaction r=9)
2
Panic
Triggers a panic alarm (audible or silent, see 6.35)
3
Fire
Triggers a fire alarm
4
24 hours
Triggers an intruder alarm even if the system is
unset (audible or silent – see 6.38)
5
Next delay
Always provides an exit delay. An entrance delay
is only provided if it is triggered shortly after a
delayed detector.
6
Instant
If activated in a set (armed) section, it triggers an
intruder alarm instantly
7
Set
Sets its own section of the system
- 11 -
Notes
(or
) =set,
(or
fig. 11 Device reactions
) =unset, both