12 Control panel programming sequences

Function
Entering enrollment mode
One wireless device (detector, keypad, key
fob, siren or sub control panel) can be enrolled
to each address from 01 to 50.
The system offers vacant addresses one by
one, if all addresses are occupied no devices
can be enrolled.
A device enrolled to address 01 to 30
disables the corresponding hard-wired input
01 to 30.
In addition to enrollment mode, devices can
also be enrolled by keying in their production
codes (see 6.42).
Exit delay time
Entrance delay time
Alarm duration time
PGX function
PGY function
Enablement of telephone number changes
in maintenance mode
Radio interference indication
Radio communication supervision
RESET enabled
Master control panel enrollment to a sub
control panel for setting (arming) control
Master code reset
Measuring signal strength
Enrolling the control panel to UC, AC or a
sub control panel
Setting (arming) without an access code
Triggered detector indication
by text on the keypad display
Confirmation of intruder alarms
In this mode, the triggering of an intruder
detector in a set (armed) section will only be
recorded to the memory as an unconfirmed
alarm and if then followed by the activation of
any other intruder detector within 40 minutes,
an alarm will be triggered. If the first triggered
detector has a DEL reaction and it is not
confirmed by any other detector, it will not
trigger an alarm after the entrance delay has
expired.
Exit delay beeps
Exit delay beeps while partially arming
JA-83K control panel installation manual
Sequence
Options
Keys:
1 and 7 = address
scrolling
holding 2
= erases the
displayed
address
1
holding 4
= erases all
addresses
#
= exiting
enrollment
mode
20x
x = 1 to 9 (x10 s =10 to 90 s)
21x
x = 1 to 9 (x 5 s = 5 to 45 s)
22x
x = 1 to 8 (min.), 9=15min
x in an unsplit system:
0
whole system set (ABC)
= PG on
1
any system part set = PG
on
2
AB set (not C) = PG on
3
Fire alarm = PG on
23x
4
Panic alarm = PG on
24x
5
Any alarm = PG on
(excluding Panic)
6
AC dropout = PG on
PG on/off (by 80 /81 for
7
PGX and 90/91 for
PGY)
8
Single 2 s pulse
(keys 8=X, 9=Y)
25x
251 = YES
26x
261 = YES
27x
271 = YES
28x
281 = YES
The sequence triggers
290
enrollment.
291
Returns master code to 1234
298
Activates measurement
The sequence triggers
299
enrollment.
30x
301 = YES
31x
311 = YES
32x
321 = YES
33x
331 = YES
341 = YES
34x
fig. 18 Summary of the programming sequences
- 17 -
Setting to
Factory
comply with
default
EN-50131-1
nothing
30s
20s
4 min.
7
on/off
80/81)
1
any
system
part set
250 = NO
NO
260 = NO
NO
270 = NO
NO
280 = NO
YES
(Un)setting the master
control panel will (un)set the
sub control panel.
The sub control panel must
be in enrollment mode.
It has no effect on other
codes and it is recorded in
the control panel memory
arrow keys scroll
addresses,
# halts measurement.
see 6.9
300 = NO
YES
310 = NO
YES
320 = NO
NO
YES
330 = NO
340 = NO
NO
Notes
 devices enroll by connecting
their power (battery) except
keyfobs which enroll by
pressing & holding a pair of
their buttons
 an occupied address is
indicated by the A indicator
being lit
 enrolling a device to a new
address will move it there
if a final door detector is used,
then x is multiplied by 30s
instead (i.e. from 30 to 270s)
0=10s (for testing)
x in a split system
0
alarm A = PG on
1
alarm B = PG on
2
entrance delay A = = PG on
3
entrance delay B = PG on
4
A set = X on, B set = Y on
5
A panic = X on,
B panic = Y on
6
Fire = X on,
AC dropout = Y on.
PG on/off (by 80 / 81for
7
PGX and 90 / 91 for PGY)
8
Single 2 s pulse
(keys 8=X, 9=Y)
see communicator
YES
30 s or longer
YES
by keying: A, B, ABC, 1, 2,
NO
3,4
allows the display of open
windows & doors,
to view details press ?
An alarm can be confirmed by
any other intruder detector in any
section which is set (armed).
The last 5 s faster
The last 5 s faster
(linked to 33x setting)
MKG51101