Operating Instructions

2.1 Placing Tool in Service

Titan-EHS, EFC, EFC/L, EHRA, EHSplus, EHRAplus and EFCplus.
Prepare your Titan
plug! Double check that the standard sockets or any adapter are correctly fitted and undamaged. Never use
damaged parts under any circumstances. Use original Titan
Replacement of the power supply plug due to nationally different power supplies resp. plug connections,
must be performed according to the Technical Order "Power/Power Supply Plug" (see Appendix).
To tighten or loosen hard/soft joints, specific torque take ups or adapters are needed in accordance with a
specific bolting application (available as accessories, see Appendix). Standard nuts/-adapters are placed
on the square drive and secured. Replacement also see Chapter Service, Paragraph 6.1.
Preparation for the Bolting:
Place the Titan
- Torque Wrench on a flat surface
®
Insert support arm/reaction arm onto toothing (8) Either secure with optional Rubber Safety Ring or
with a special DMA (Safety screw is integrated), see Drwg. DMA-Examples with Titan
Place standard nut/-connector on square drive (7)
Titan
-STACO
®
Standard Nut
WARNING!
Beware of high hydraulic pressure components.
-Torque Wrench for your specific bolting application, before you connect the
®
IMPORTANT!
Titan
Reaction Arm resp.
Torque Sensor
6
- spare parts and accessories only.
®
Titan
-STACO
®
Standard Nut
-DMA
®
Titan
-STABI
®
Standard Connector
-EFC
®