OPERATION CHECK
● Disconnect the magnetic switch wire connector.
● Apply battery voltage between terminals, when the
yellow / red wire is connected to the positive (+)
battery terminal and the green / yellow wire to the
negative (-) battery terminal.
● If there is continuity between battery and motor
terminal, it is normal.
STARTER SYSTEM