Slide Scanner Repair Manual
Diagnostics and Troubleshooting
Figure 5-12. Chevron test pattern
RSS Mean Misalignment result - 0.04 Pixels which is within the spec of less than .707 pixels.
This number is a combination of the vertical and horizontal static misalignments. Note that in
the main test panel this misalignment is also called Mean offset. This number is the DC
component of misalignment.
135