Hex Code
Error Definition
00 00 80 00 (Cont'd)
*
01 00 00 00
DSPTIMEOUT:
DSP communications
to slide scanner timed
out.
*
02 00 00 00
DSPFLTERROR:
DSP communications
to slide scanner has
faulted.
*
04 00 00 00
DSPSYNCERROR:
DSP lost
synchronization t
during acquisition.
*
08 00 00 00
DSPSTATUSERROR:
DSP has a Status
error from last
operation.
*
10 00 00 00
DSPBADSTATUS:
DSP communications
to slide scanner is
out of synchronization.
*
SprintScan PLUS only.
* *
Not Used in SprintScan PLUS.
Table 5-3. Operational Error Messages (Cont'd)
Probable Cause
Defective Main
Controller PC Board.
Defective Main
Controller PC Board.
Defective Main
Controller PC Board.
Defective Main
Controller PC Board.
Defective Main
Controller PC Board.
Diagnostics and Troubleshooting
Action
• Improperly connected cable from
• Improperly connected ribbon
Note: If all else fails, replace
Replace Main
Controller PC Board.
Replace Main
Controller PC Board.
Replace Main
Controller PC Board.
Replace Main
Controller PC Board.
Replace Main
Controller PC Board.
104
power supply to J5 on main
controller PC board.
cable from main controller PC
board to sensor (CCD) PC
board.
main controller and/or
sensor (CCD) PC
boards.