Setting; Test - SGM Giotto 1500 Instruction Manual

Table of Contents

Advertisement

GB
Fixture operating time meter
SIGNAL=DMX
Calibration of the PAN and TILT "home" position and of the color
wheel "white" position

SETTING

PAN=0
TILT=0
COLOR=0
Test functions

TEST

TEST=RESET
TEST=RESET
Giotto 1500
This menu is only for reading and allows to verify which type of input signal
is used (DMX o RS232). The signal is automatically recognized.
To visualize the required signal, procede as follows:
1. Use the DIAL to find "SCANNER HOUR" menu. The fixture life hours
will be displayed automatically.
SETTING
On the setting menu it is possibile to calibrate the PAN and TILT's "home"
position and the color wheel's "white" starting position. To do the
calibartion please proceed as follows:
1. Connect Giotto 1500 to the power supply, wait that the reset operation
are completed.
2. Use the DIAL to find "SETTING" menu.
3. Insert the access code to the SETTING's sub-menu.
4. Use the DIAL to select the option desired (PAN, TILT, COLOR) .
5. Press ENTER to confirm. The message on the display will start to flash.
6. Regulate the offset by the DIAL.
7. Press ESC to confirm (the message will stop flashing) and go back to
the SETTING's sub-menu.
8. Once performed all the calibrations, keep pressed ESC to go out from
the setting menu.
TEST
Test programs can be used in the event of it being necessary to check the
correct operation of the fixture or some of its parts.
To select the required test program, proceed as follows:
1. Connect Giotto 1500 to the power supply, wait that the reset operation
are completed.
2. Use the DIAL to find "TEST" menu.
3. Press ENTER to confirm. The message on the display will start to flash.
4. Use the DIAL to select the program corresponding to the part of the
fixture to be tested.
5. Press ENTER to run the test program.
6. Press ESC to quit the test functions.
- 61 -
SGM
User's Manual 1.02

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents