Modules replacement procedure:
1. Remove the lid through the four screws (Ref. Paragraph 2.12 – Access to the inside)
2. Disconnect the connectors, which are on the sides of the head.
Connectors 1, 2, 3 in Spot – Profile – Digital configurations Pict. 1
Connectors 1, 2 in Wash configuration Pict. 2.
3. Loosen to a quarter of turn the screws related to the fixing of each module
8 screws for Spot – Profile – Digital configuration. Pict 1
6 screws for Wash configuration. Pict 2
4. Draw out the module as needed. Example Pict. 3, Pict. 4, Pict. 5 Refer to the table below to configure
Giotto 1500 in the 4 modules:
Spot – Wash – Profile – Digital.
5.
Pict.3 – Zoom Focus Module
Digital Module
1. When inserting the digital module, use the black lever (as shown in the picture), in order to avoid
interferences with the mirror. Pict. 1
When the module is inserted, release the lever to let the mirror open completely.
2. Insert the connector of the Digital module. Pict. 2
3. Insert the connector beetwen the Digital module and ZOOM FOCUS DIGITAL Pict. 3
Pict. 1
Giotto 1500
Pict. 4 – Wash Module
Pict. 2
- 29 -
SGM
Pict. 5 – CMY Module
Pict.3
User's Manual 1.02