Light Path Diagnostics Panel - IBM eServer 342 xSeries User Reference Manual

Hide thumbs Also See for eServer 342 xSeries:
Table of Contents

Advertisement

Light Path Diagnostics panel

The following illustration identifies the individual LEDs on the Light Path Diagnostics
panel.
Table 3. Diagnostics panel LEDs.
34
IBM xSeries 342: User's Reference
MEM
PS1
CPU
PS2
PCI A
PS3
PCI B
NON
PCI C
OVER
VRM
NMI
DASD
TEMP
SP
FAN
REMIND
Diagnostic
panel LED
PS1
Power supply 1 failure.
PS2
Power supply 2 failure if installed.
PS3
Not used.
NON
Server power supplies are no longer redundant (applicable only with
redundant power feature).
OVERSPEC Overspecification. The system has exceeded the power capabilities (max
rating) of the installed power-supply units.
NMI
Nonmaskable interrupt occurred.
TEMP
System temperature exceeded maximum limit. Other LEDs will be on to
identify the location of the temperature problem.
FAN
A fan failed or is operating slowly.
MEM
Memory failure. One or more dual inline memory modules (DIMMs) failed.
CPU
One or both microprocessors failed or one is seated in wrong connector.
PCI A
Error occurred on an adapter in PCI slot 1, or one of the PCI devices
integrated on the system board.
PCI B
Error occurred on an adapter in PCI slots 2 or 3, or one of the PCI devices
integrated on the system board.
PCI C
Error occurred on an adapter in PCI slots 4 or 5, or one of the PCI devices
integrated on the system board.
SP
System management subsystem detected an error.
VRM
Error on voltage regulator module.
DASD
The SCSI backplane (if any) or a device connected to a SCSI bus failure.
Description

Advertisement

Table of Contents
loading

Table of Contents