Error Logs - IBM eServer 342 xSeries User Reference Manual

Hide thumbs Also See for eServer 342 xSeries:
Table of Contents

Advertisement

POST message
00180800
An unsupported PCI device is installed.
Action: Remove the PCI adapters. If you can start the server without the adapters, reinstall
each adapter one at a time and retest after each is reinstalled. When an adapter fails, replace it.
If the problem remains, call for service.
00181000
PCI error.
Action: Remove the PCI adapters. If you can start the server without the adapters, reinstall
If the problem remains, call for service.
01295085
The ECC checking hardware test failed.
Action: Call for service.
01298001
No update data is available for processor 1.
Action: Update the system BIOS to a level that supports the microprocessors installed in the
01298002
No update data is available for processor 2.
Action: Update the system BIOS to a level that supports the microprocessors installed in the
01298101
The update data for processor 1 is incorrect.
Action: Update the system BIOS to a level that supports the microprocessors installed in the
01298102
The update data for processor 2 is incorrect.
Action: Update the system BIOS to a level that supports the microprocessors installed in the
01298200
Microprocessor speed mismatch
Action: The microprocessors installed do not run at the same speed; install microprocessors
I9990301
A hard disk drive error occurred.
Action: Call for service.
I9990305
POST could not find an operating system.
Action: Install an operating system. If you have already installed the operating system, check
If you cannot reinstall the operating system, call for service.
I9990650
AC power has been restored.
Action: No action is required. This message appears each time AC power is restored to the
Other Numbers
POST found an error.
Action: Follow the instructions on the screen.
Table 13. POST error messages.

Error logs

The POST error log contains the three most recent error codes and messages that
the system generated during POST. The System Error Log contains all error
messages issued during POST and all system status messages from both the system
92
IBM xSeries 342: User's Reference
each adapter one at a time and retest after each is reinstalled. When an adapter fails,
replace it.
server.
server.
server.
server.
with identical speeds.
the drive startup sequence. If the drive sequence is correct, run the diagnostic tests to
verify that the hard disk drive is functioning correctly. If there is a problem with the hard
disk drive (such as a bad sector), you might need to reinstall the operating system.
server after an AC power loss.