POST message
1301
Cable to Information LED panel not detected.
Action: Make sure that the cable to the operator information panel is connected.
If the problem remains, call for service.
1302
Cable to Power and Reset pushbuttons not detected.
Action: Make sure that the cable to the Power and Reset pushbuttons is connected.
If the problem remains, call for service.
1303
I2C cable to Power Backplane not detected.
Action: Make sure that the cable to the power backplane is connected.
If the problem remains, call for service.
1304
Cable to Diagnostic LED panel not detected.
Action: Make sure that the cable to the diagnostic LED is connected.
If the problem remains, call for service.
1600
The system management adapter is not functioning.
Action: 1.
If the problem remains, call for service.
1601
A system management adapter Flash update is needed.
Action: Download and install the latest Advanced System Management flash update.
1800
A PCI adapter has requested a hardware interrupt that is not available.
Action: 1.
1962
No valid startup devices were found. The system cannot find the startup drive or operating
system.
Action: Be sure that the drive you want to start from is in the startup sequence.
If the same error message appears, call for service.
Table 13. POST error messages.
Verify that the jumpers for the system-management processor are set correctly.
2.
Disconnect the server from all electrical sources, wait for 30 seconds, reconnect
the server to the electrical sources, and restart the server.
Make sure that the PCI adapter and all other adapters are set correctly in the
Configuration/Setup Utility program. If the interrupt resource settings are not
correct, change the settings.
2.
If all interrupts are being used by other adapters, you might need to remove an
adapter to make an interrupt available to the PCI adapter, or force other adapters
to share an interrupt.
1.
Select Start Options from the Configuration/Setup Utility program main menu. If
you are unable to set the startup sequence, call for service.
2.
Check the list of startup devices in the Startup device data fields. Is the drive you
want to start from in the startup sequence?
Yes
Exit from this screen; then, select Exit Setup to exit the
Configuration/Setup menu. Go to step 3..
No
Follow the instructions on the screen to add the drive; then, save the
changes and exit the Configuration/Setup menu. Restart the server.
3.
Is an operating system installed?
Yes
Turn off the server. Go to step 4..
No
Install the operating system in your server; then, follow your operating
system instructions to shut down and restart the server.
4.
During server startup, watch for messages indicating a hardware problem.
Description
Chapter 6. Solving problems
89